Connection Method of Function Controller

Always power off and perform work as below where connection of the function controller is required.
1
Connect the function controller as right figure so that symbols below CN_REMO Terminal Block of the
central controller and color of cable connected the function controller correspond.
Central controller
Function controller
CN_REMO
RD terminal (12V)
YL terminal (signal)
BR terminal (GND)
2
Connect red wires and brown wires to the relevant terminal of the central controller CN_REMO
respectively as right figure where the central controller is installed as right figure.
3
Close the central controller case and check operation after application of power.
Caution
1. Cables adhered to the function controller as possible for communication wires between function controller and
central controller.
2. Use 3P-0.75 Square Shield wires where cable extension is required.
3. Install cable length is within 1m.
4. If wiring is not proper, the product may be damaged or not operate when power is applied.
cable
Red
Yellow
BR YL
BR
YL RD
Grey
RD
PQRCHCS0
Owner's & Installation Manual 9
Before Use
PQRCHCS0
Defrost
Preheat Out door
Slo
Lo
Med
Hi
Po
Cooling Heating Auto Dry Fan
FAN
MODE
SPEED
Defrost
Preheat Out door
Slo
Room Temp
Lo
Total on
Med
Central Run
Hi
Po
Cooling Heating Auto Dry Fan
FAN
MODE
SEARCH
SPEED
Room Temp
Total on
Central Run
SEARCH

Advertisement

Table of Contents
loading

Table of Contents