Monessen Hearth ICFDV30LNTSC Installation And Operating Instructions Manual page 34

Icfdv series direct vent gas fireplace insert
Table of Contents

Advertisement

ICFDV Fireplace Insert
n using the Mounting Base
The transmitter comes with a mounting base which allows
you to hang the transmitter on the wall.
1. Secure the mounting base
on the wall with supplied
screws. For best viewing
angle, make it the same
height as your eyes.
2. Hang the transmitter on the
hook of the mounting base,
then push down so the
transmitter is flush to the
mounting base.
Symptom
1. Battery icon on LCD on transmitter
2. LCD display is blank
3. LCD display shows "funny" display
4. Appliance does not come on
5. Blower is not on after the fireplace is
turned on
34
TOuCh SCReeN ReMOTe CONTROL OpeRATION
Figure 42
FP2674
TROUBLESHOOTING
mounting base
Causes
1. Low Battery
2. The transmitter did not match
with the receiver
3. Transmitter measures temp-
erature exceeding 99 degrees
Fahrenheit and shows "HI" on
LCD
4. Distance between the transmitter 1. Make sure the opening distance is
and receiver is more than 30 feet
5. Blower setting is off
6. Blower delay setting is set too
high
Action
1. Replace batteries. Change batte-
ries every 6 months.
2. Check battery installation or re-
place batteries.
3. Reset the transmitter (see "Reset
ting the Transmitter" section).
1. Make sure the transmitter has
learned to the receiver.
1. Move transmitter to a cooler place
and wait until temperature drops
below 99 degrees.
less than 30 feet.
1. Press FAN key to select Fan
speed you desire.
1. Press and hold FAN key to set
desired ON/OFF delays. This is
done in minutes.
20304164