Check Gas Pressure - Monessen Hearth ICFDV30LNTSC Installation And Operating Instructions Manual

Icfdv series direct vent gas fireplace insert
Table of Contents

Advertisement

ICFDV Fireplace Insert
1. Check gas type. The gas supply must be the same as
stated on the appliance's rating decal. If the gas supply
is different from the fireplace, STOp! Do not install the
appliance. Contact your dealer immediately.
2. To ease installation, a 24" (610 mm) flex line with manual
shut-off valve has been provided with on this appliance.
Install and attach 1/2" gas line onto shut-off valve.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to
the fireplace for leaks. Use a solution of 50/50 water
and soap solution or a gas sniffer.
4. To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
Figure 13. After taking pressure reading, be sure and
turn captured screw clockwise firmly to reseal. Do not
over torque. Check test points for gas leaks.
Do not use open flame to
check for gas leaks.
16
Pressure Outlet
Figure 13 -
Signature Command Valve
FP1909a
signature command valve
alternate view
8/08

CheCK GAS pReSSuRe

Pressure Inlet
Pilot Adjust-
ment Screw
20304164

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icfdv30cntsc

Table of Contents