Multi-Connector Cable - Axis Q6032-C Installation Manual

Q60 series ptz dome network camera
Hide thumbs Also See for Q6032-C:
Table of Contents

Advertisement

Page 12

Multi-Connector Cable

The supplied multi-connector cable is required in order to maintain the camera's IP rating.
Connect the multi-connector cable to the camera's multi-connector and to the
1
8
connectors in the supplied media converter switch, see illustrations on page
2
7
9
page 6 and page 8. The cable provides the following signals:
3
6
•DC power
4
5
•Network (Ethernet 10/100Base-T)
•I/O
Function
Pin
Configurable
2, 7
(Input or
Output)
RX+
3
RX-
4
TX+
5
TX-
6
GND
8
12 V Power
1, 9
Wire
Notes
Blue, yellow
Digital input – Connect to GND to activate, or
leave floating (unconnected) to deactivate.
Digital output – Internal connection to ground
when activated, floating (unconnected) when
deactivated. If used with an external relay, a
diode must be connected in parallel with the
load, for protection against voltage transients.
Green/white
Ethernet – receiving
Green
Ethernet – receiving
Orange/white
Ethernet – transmitting
Orange
Ethernet – transmitting
Black
Ground
Red
Used to power camera
AXIS Q6032-C/Q6034-C/Q6035-C Installation Guide
Specifications
0 to +30 V DC
Max load =100 mA
Max voltage =
+30 V DC
12 - 13.2 V DC
Max load = 6 A