Vbcv Wall Custom Ventilator System; Dimensions & Specifications; Installing Hood Canopy - Viking 24" Installation Manual

Professional hoods
Table of Contents

Advertisement

Dimensions & Specifications
(VBCV Wall Custom Ventilator System 30", 36", 42", 48", 54", 60" & 66")
*For best results,
B*
center the unit over
the burners of the
cooking product
(front to back; right
to left).
B B o o t t t t o o m m C C u u t t o o u u t t D D i i m m e e n n s s i i o o n n s s
Wall Hoods
Description
A (Hood Width)
30" W.
27-7/16" (69.7 cm)
36" W.
33-7/16" (84.9 cm)
42" W.
39-7/16" (100.2 cm)
48" W.
45-7/16" (115.4 cm)
54" W.
51-7/16" (130.7 cm)
60" W.
57-7/16" (145.9 cm)
66" W.
63-7/16" (161.1 cm)

VBCV Wall Custom Ventilator System

Description
30"
36"
42"
Number of lights
2
2
2
Number of filters
2
2
2
Heat lamps
1
1
1
VINV300/
VINV300/
VINV600/
Interior ventilator kits
600/1200*
600/1200*
1200*
Exterior ventilator kits
DEV900/
DEV900/
DEV900/
1200*
1200*
1200*
DIL900/1200
DIL900/1200 DIL900/1200
In-line ventilator kits
7"/10"
7"/10"
7"/10"
Interior duct size
(17.8/25.4 cm)
(17.8/25.4 cm)
(17.8/25.4 cm)
Exterior duct size
5.9/9.0
5.9/9.0
5.9/9.0
Interior—Maximum amps
8.7/6.0
8.7/6.0
8.7/6.0
Exterior—Maximum amps
6.0/7.9
6.0/7.9
6.0/7.9
In-Line—Maximum amps
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; ll products must be hard wired with 2-
wire with ground. n interior- or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods.
A*
M M a a k k e e s s u u r r e e t t h h e e b b a a c c k k w w a a l l l l
o o f f t t h h e e c c u u s s t t o o m m h h o o o o d d
c c a a n n o o p p y y i i s s f f l l u u s s h h w w i i t t h h t t h h e e
c c u u t t o o u u t t s s o o t t h h e e v v e e n n t t i i l l a a t t o o r r
s s y y s s t t e e m m m m a a y y b b e e m m o o u u n n t t e e d d
a a s s s s h h o o w w n n o o n n p p a a g g e e 2 2 5 5 . .
B (Hood Depth)
21-7/16" (54.5 cm)
21-7/16" (54.5 cm)
21-7/16" (54.5 cm)
21-7/16" (54.5 cm)
21-7/16" (54.5 cm)
21-7/16" (54.5 cm)
21-7/16" (54.5 cm)
48"
54"
60"
66"
3
3
4
4
3
3
4
4
2
2
2
2
VINV1200* VINV1200* VINV1200* VINV1200*
DEV1200*/
DEV1200*/
DEV1200*/
DEV1200*/
1500**
1500**
1500**
1500**
DIL1200
DIL1200
DIL1200
DIL1200
10"
10"
10"
10"
(25.4 cm)
(25.4 cm)
(25.4 cm)
(25.4 cm)
10" (25.4 cm)
11.5
11.5
11.9
11.9
8.5/9.2
8.5/9.2
8.9/9.2
8.9/9.2
10.3
10.3
10.7
10.7
26

Installing Hood Canopy

)
(Custom Hood Canopy Cutouts
C C u u s s t t o o m m H H o o o o d d
C C a a n n o o p p y y
A A
1) Position ventilator
system inside of the
custom hood canopy
and center it front to
back and left to right.
2) Bottom mounting holes
fasten ventilator system
to bottom of custom
hood canopy with the
screws provided.
27
B B
B B u u i i l l t t - - I I n n V V e e n n t t i i l l a a t t o o r r
S S y y s s t t e e m m
3) OPTIONAL
Rear mounting holes fasten
ventilator system to rear of
custom hood canopy.

Advertisement