Convection Circuit
L1
HI
140 C
LIMIT
284 F
TCO
N.C.
R
COM
N.O.
K3
R
R
J14
J7-7
R
J5-1
R
J5-5
R
K12
Clean Circuit
N.C.
R
COM
N.O.
K3
R
J14
R
J14
R
K12
R
N.C.
S
K7
COM
N.O.
G
K7
K3
K5
N.C.
COM
N.O.
K4
K1
J5-2
K1
Closed above 200 F
V
J2
N.C.
G
COM
N.O.
K7
O
K8
J7-2
K11
K13
N.C.
CONVECTION
COM
ELEMENT 1
RW
N.O.
K10
47Ω
CONVECTION
ELEMENT 2
RW
J7-4
62Ω
YN
CW
J7-12
92Ω
J7-10
CCW
M
77Ω
YR
CONVECTION
FAN
OW
LOW SPEED
M
20Ω
COOLING
FAN
OVEN
LAMP
Y
RN
HIGH SPEED
M
COOLING
FAN
M
LATCH
MOTOR
– 83 –
N
C
J11
N.C.
C
COM
N.O.
K14
C
W
W
W
W
CYCLING
CONTACTS
L2
B
K14

Hide quick links: