Control Panel; Surface Components - GE Monogram ZDP486ND Technical Service Manual

Professional range and rangetops
Hide thumbs Also See for Monogram ZDP486ND:
Table of Contents

Advertisement

WARNING: Sharp edges may be exposed when
servicing. Use caution to avoid injury. Wear Kevlar
gloves or equivalent protection.

Control Panel

It is necessary to remove the control panel from the
range or rangetop chassis and place it in the service
position to access certain components.
To place the control panel in the service position:
Note: It will be necessary to pull the rangetop
approximately 10 inches out from its installation.
1. Remove left and right side grates, surface
burner knobs, grill and griddle control knobs.
2. On range models:
a. Remove the 2 Phillips-head screws that
attach the griddle control bezel to the
control panel.
b. Remove the 2 Phillips-head screws that
attach the griddle control to the manifold
bracket.
Bezel Screw
Control Screw

Surface Components

3. Remove the 2 Phillips-head screws within each
4. Remove the T-15 Torx screws from the bottom
5. Remove the Phillips-head screw at each front
Control Screw
Bezel Screw
– 30 –
bezel that attach the bezel to the manifold
brackets.
of the control panel.
corner that attaches the front of the side trim to
the control panel.
Note:
A ground wire at each end of the panel allows
the panel to be lowered without falling.
Before lowering, protect the bottom of the front
panel from scratches caused by the lock motor
arm (range models) or front frame edge.
If the range has a grill, use caution when
lowering the control panel to prevent damage to
the switches mounted at the bottom of the grill
valve.
(Continued next page)