MAINTENANCE

Be sure to disconnect the power cord from the
wall outlet or turn off the circuit breaker before
performing any maintenance.
CLEANING THE FILTERS
The air fi lter sign lamp on the display panel will turn
on to denote the air fi lter needs cleaning if the total
operating time is accumulated to 300 hours.
The lamp will turn off when the operation is
stopped.
(Accumulated operating time will be reset to "0" at
this moment)
Air fi lter sign lamp
1
Turn off the unit.
2
Remove the fi lters.
1 Lift the open panel.
2 Push the air fi lters up slightly to unlock them.
3 Pull the air fi lters down to remove them.
1
2
3
Take off the air purifying fi lters from
the air fi lters.
4
Clean the fi lters.
Use a vacuum cleaner to remove dust. If the
fi lters are dirty, wash them with warm water
and a mild detergent. Dry fi lters in the shade
before reinstalling.
5
Reinstall the air purifying fi lters.
6
Reinstall the fi lters.
1 Reinstall the fi lters in the original positions.
2 Close the open panel.
3 Push the arrow-marked of the panel fi rmly
to lock it in place.
3
2
1
3
E-12
CLEANING THE UNIT AND THE
REMOTE CONTROL
• Wipe them with a soft cloth.
• Do not directly splash or pour water on them. It
can cause electrical shock or equipment damage.
• Do not use hot water, thinner, abrasive powders or
strong solvents.
MAINTENANCE AFTER AIR
CONDITIONER SEASON
1
Operate the unit in the SELF CLEAN
operation to allow the mechanism to
thoroughly dry.
2
Stop the operation and unplug the unit.
Turn off the circuit breaker, if you have
one exclusively for the air conditioner.
3
Clean the fi lters, then reinstall them.
MAINTENANCE BEFORE AIR
CONDITIONER SEASON
1
Make sure that the air fi lters are not
dirty.
2
Make sure that nothing obstructs the
air inlet or outlet.