Page 22
Auto Arming (Not for UL Installations)
AUTO ARM allows the User to automatically arm the system at a specified time of the day and on specific days of the
week. Schedule a specific closing time on any/all day(s) of the week. After a specific Fail-to-Close Window Start
Time, if the user has not Armed the system during the Window Length, and the system has been instructed to "Fail-to-
Close' and 'Auto Arm if not closed at end of Window" then the system will arm, providing a 15 minute warning. CAU-
TION: If Automatic Interior Bypass is selected, panel will Auto Arm in STAY Mode.
Delaying an Auto Arm (Not for UL Installations)
During the 15 minute pulsating sounder warning of an Auto Arm, a User can press the
AUTO ARM / PRESS 1-4 / N" is displayed. Enter the number of hours (1-4) to delay arming, followed by the
If "DELAY AUTO ARM Y/N" is displayed, press the "NEXT/YES" button. The sounder can be silenced by pressing the
button during the 15 minute interval, but will come back on in the last 1 minute. This feature may be canceled
C
by arming and disarming the keypad.
EZ Arm (Easy Arm)
EASY ARM provides one button arming for non-security critical premises. Select Easy Arming for each Keypad, with
optional reporting of Easy Arm Closings as User 67. Disarming still requires a valid user code.
To arm, press the
To arm, press and hold
Keyswitch Arming
KEYSWITCH ARMING allows a zone input to be used to arm/disarm. The area will arm/disarm when the zone is
momentarily shorted through a Momentary Switch. An end-of-line resistor must be used. Select Keyswitch Arm to
optionally report as User 68.
Maintained-Key Input Arming
KEYSWITCH ARMING with MAINTAINED-KEY INPUT ARMING is similar to Keyswitch arming, except the zone input
must remain shorted to be armed and remain open to be disarmed.
Remote Arming (Not for UL Installations)
REMOTE ARMING allows computer software control of arming/disarming of the system for non-security critical
installations. Select Remote Arm to optionally report as User 34.
Priority Arming
A 2-second tone and "CAN'T ARM SYSTEM/ZONE FAULTED" displayed when attempting to arm indicates a priority condition;
that is, a problem exists on at least one zone that has been designated as a Priority Zone, or a system trouble exists.
The trouble(s) must be corrected before the panel can be armed.
automatically scroll through all unsecured zones. If a system trouble is indicated, it will display the system trouble.

BYPASSING ZONES

Selective Bypass (Bypassing Specific Zones)
A Selective Bypass will bypass a specific zone that has Selective Bypass enabled, by pressing the
followed by the zone number. The zone will be unbypassed the next time the system is disarmed. Note: Security
Bypass is a option that requires a valid User Code to bypass zones. This feature is enabled at the factory and can be
disabled using existing address (global "Enable Security Bypass"). In addition, when new User Codes are entered, the
"User Area Option" must be enabled to allow the new User Code to bypass zones. See Programming Instructions
(WI995 or WI1182) for more information.

UNBYPASSING ZONES

(Unbypassing Specific Zones)
To unbypass a specific zone that has been bypassed, press the
zone will be unbypassed the next time the system is armed.
GEM-P816 Installation Instructions
D
button for "Classic" keypads;
or
for 3 seconds for "K Series" keypads.
P
Q
R
The display will read "ZONE FAULTED", then
button followed by the zone number. The
B
NAPCO Security Systems
R
button, until "TO DELAY
U
button.
button