Chimney System; General Maintenance; Gaskets - Jøtul F600 Installation And Operating Instructions Manual

Table of Contents

Advertisement

USA/cAnAdA
(marked on the perimeter) should always be facing outward. It
is extremely important to tighten the glass clips slowly and in
a repeating pattern, like tightening the lugs on an automobile
wheel.
It may be necessary to retighten the glass clips after the stove
has burned and the gasketing has been seated.
Important:
Replace glass only with a ceramic glass panel specifically
designed for the Jøtul F 600. Do not use substitutes. Replacement
glass panels can be ordered through your Jøtul dealer.

6.3 Chimney System

The Jøtul F 600 is designed to burn cleanly and efficiently
when used according to the guidelines in this manual. In
order to maintain proper performance, you should inspect
the chimney and chimney connector at the beginning of
each heating season and then, twice a month during the
heating season. Clean the chimney whenever creosote
and fly ash accumulation exceeds 1/4 inch in any part of
the system.
Chimney brushes are available from your local Jøtul dealer
or hardware supply store. Your dealer can also refer you
to a reputable, professional chimney sweep who will have
all the equipment to ensure a complete and proper job.
Failure to keep the chimney system free of creosote and
build up could result in a serious chimney fire.
10

7.0 General maintenance

Like your car, regular maintenance prolongs the life of your stove.
The following procedures do not take long and are generally
inexpensive, but when done consistently, increase the life of your
stove and in turn, increase your years of enjoyment.
Enamel Care:
• DO NOT ATTEMPT TO CLEAN HOT ENAMEL SURFACES. Clean
only cold enamel surfaces with a soft damp cloth and polish
with a clean dry cloth.
DO NOT USE SOAPY OR ABRASIVE SOLUTIONS. These can
cause stains. Coffee, tea, and fruit jucies will also cause stains.
• AVOID CONTACT WITH METAL OBJECTS. Trivets, kettles, or
pots, can damage the enamel.
• Empty stove of all soot and ashes. Only use a vacuum for this
job if the vacuum is specifically designed for ashes.
• Inspect the stove: Using a strong light inspect the stove inside
and out for cracks or leaks. Replace all cracked parts and repair
any cement leaks with furnace cement.

7.1 Gaskets

Check door and window gaskets for tightness.
To check the seal of the front doors, close and latch the doors on a
dollar bill and slowly try to pull the dollar bill free. If it can be easily
removed then the seal is too loose. Check several spots around
the door, and repeat the procedure on the ash pan door as well.
• If gaskets need to be replaced, scrape out the old gasket and
cement and clean the area with a wire brush.
• Apply a small bead of cement and push in the new gasket.
• After closing and latching the doors wipe clean any excessive
cement that has come from beneath the gasketing.
Description
Size
Right door,
ld375
Left door,
ld375
Left door, middle
ld250
Right glass,
ld250
Left glass,
ld250
Ash pan door,
ld250
Right side load door,
ld375
The Jøtul F 600 is designed to burn cleanly and efficiently when
used according to the guidelines expressed in these operating
instructions. However, to maintain the proper performance, a
yearly chimney inspection and cleaning is necessary. Failure to
keep the chimney system free of creosote and build up could
result in a serious chimney fire.
Length
ø9,5 mm (3/8")
900 mm (36")
ø9,5 mm (3/8")
900 mm (36")
ø6,4 mm (1/4")
410 mm (18")
ø6,4 mm (1/4")
1050 mm (42")
ø6,4 mm (1/4")
1050 mm (42")
ø6,4 mm (1/4")
1100 mm (45")
ø9,5 mm (3/8")
1400 mm (56")

Advertisement