Table of Contents

Advertisement

USA/cAnAdA
Part list for Jøtul F 600
Pos.
no. Description
2
Tube Frame Holder
3
Handle
4
Ash House Compl.
5
Ash Door
6
Smoke Outlet
7
Fire Grate
8
Leg
9
Decorative Cover Side
10
Door Right w/o Glass, Ver 3
11
Door Left w/o Glass, Ver 3
12
Bottom
13
Inner Bottom, Front Part
14
Inner Bottom, Rear Part
15
Rear Plate
17
Air Manifold
18
Front
19
Inner Front
20
Side Right
21
Side Left
22
Ash Lip Front
23
Top
24
Tube Holder Upper Right
25
Tube Holder Upper Left
26
Tube Holder Bottom Right
27
Tube Holder Bottom Left
28
Inspection Cover
29
Side Door
30
Burnplate Side Door
31
Burnplate Left
32
Burnplate Rear
33
Ash Lip Side
34
Air Valve
35
Baffle Plate
36
Top Cover
37
Nut Stainless
38
Screw Hexagon Stainless
39
Screw Hexagon
40
Screw Collar Hexagon
41
Screw Collar Hexagon
42
Screw Selfthread
43
Screw Collar Hexagon
44
Screw Collar Hexagon
45
Nut Hexagon
46
Screw Panh. (Front Door)
47
Washer
48
Latch Bolt Ash Door
49
Screw Allen
50
Screw Hexagon Stainless
51
Screw Collar Hexagon
52
Screw Collar Hexagon
53
Screw Collar Hexagon
54
Nut Collar Hexagon
55
Washer
56
Wooden Knob Ash Door
57
Spring for Latch Bolt
58
Hinge Pin Front/Side Door
59
Screw Syl. Head
60
Gasket (Door to Front)
61
Latch
62
Latch Bolt
63
Glass Clip
64
Ash Pan
65
Handle for Air Vent
68
Hinge Pin, Ash Door
69
Gasket (Ash Door)
70
Gasket (Glass)
71
Gasket (Top)
72
Gasket (Ash House)
73
Gasket (Left Door Middle)
74
Sleeve for Door Hinge
75
Gasket (Side Door)
76
Gasket (Smoke Outlet)
77
Tube First From Front
78
Tube Second From Front
79
Tube Third From Front
80
Tube Forth From Front
82
Bottom Heatshield
83
Heatshield Top Exit
84
Rear Heatshield
18
Pos.
no. Description
85
Air Restrictor
86
Insulation Blanket
87
Glass
88
Front Door Hinge
89
Gasket (Top Cover)
90
Shaft Collar Ø6 X Ø12 X 6 mm
91
Latch Bolt Side Door
92
Washer
93
Latch
94
Washer
95
Washer, Insulating
96
Wooden Knob Side Door
97
Distance Sleeve for Side Door
98
Screw Pan Head
99
Pin
100 Air Chamber Complete
101 Handle Side Door Complete
102 Adapter Outside Air
Alternate floor protection
All floor protection materials must be non-combustible ie. metal,
brick, stone, mineral fiber boards). Any combustible material may
not be used.
The easiest means of determining if a proposed alternate floor
material meets requirements listed in this manual is to follow
this procedure.
R-value = thermal resistance
k-value = thermal conductivity
C-value = thermal conductance
1. Convert the specification to R-value;
a. If R-value is given, no conversion is needed.
b. If k-value is given with a required thickness (T) in inches:
R=1/k X T.
c. If C-value is given: R=1/C.
2. Determine the R-value of the proposed alternate floor
protector.
a. Use the formula in Step 1 to convert values not expressed
as "R".
b. For multiple layers, add R-values of each layer to
determine overall R-value.
3. If the overall R-value of the system is greater than the R-value
of the specified floor protector, the alternate is acceptable.
Example:
The specified floor protector should be 3/4" thick material with a
k-factor of 0.84. The proposed alternate is 4" brick with a C-factor
of 1.25 over 1/8" mineral board with a k-factor of 0.29.
Step A. Use formula above to convert specifications
to R-value. R=1/k X T= 1/.84 X .75 = .893
Step B. Calculate R of proposed system.
4" brick of C-1.25, therefore
R brick = 1/C = 1/1.25 = 0.80.
1/8" mineral board of k = 0.29 therefore
R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board=
0.8 + 0.431=1.231
Step C. Compare proposed system R = 1.231 to specified R of
0.893. Since R is greater than required, the system is acceptable.
Definitions:
Thermal conductance =
C =
Btu
=
(hr)(ft
)(F)
(m
2
Thermal conductivity =
k =
Btu
=
W
(hr)(ft
)(F)
(m
2
2
Thermal resistance =
R =
Btu
=
(hr)(ft
)(F)
2
Alcove installations require noncombustible hearth materials
having a minimum insulating R-value of 0.5.
W
)(K)
2
=
(Btu)
)(K)
(hr)(ft)(F)
(m
)(K)
=
(Btu)(inch)
2
W
(hr)(ft
)(F)
2

Advertisement

Table of Contents
loading

Table of Contents