ASROCK E3C224D4I-14S User Manual page 28

Server/workstation motherboard
Table of Contents

Advertisement

Non Maskable Interrupt
Button Header
(NMI_BTN1)
(see p.7, No. 27)
Intelligent Platform
Management Bus header
(4-pin IPMB_1)
(see p.7, No. 26)
Baseboard Management
Controller SMBus Headers
(5-pin BMC_SMB_1)
(5-pin BMC_SMB_2)
(see p.7, No. 10, 23)
Mini-SAS Connectors
(SAS_0_3)
(SAS_4_7)
(see p.7, No. 15, 21)
Mini-SAS/SATA
Connector
(SATA_0_3)
(see p.7, No. 13)
22
GND
1
CONTROL
No connect
GND
IPMB_SCL
IPMB_SDA
BMC_SMB_PRESENT_1_N
Power
BMC_SMBCLK7
GND
BMC_SMBDATA7
Please connect a NMI device
to this header
This 4-pin connector is used
to provide a cabled base-board
or front panel connection for
value added features and 3rd-
party add-in cards, such as
Emergency Management cards,
t h a t p r o v i d e m a n a g e m e n t
features using the IPMB.
his header is used for the SM
BUS devices.
hese two connectors are used
to connect the mini-SAS ports
on the backplanes.
T h i s c o n n e c t o r i s u s e d t o
connect the SATA port on the
backplane.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E3c224d41-14s rack

Table of Contents