Contents 1. Legal information ............................... 2. Description .................................. 3. Safety 5–8 .................................... 3.1 GSM specific ................................3.1.1 General ................................3.1.2 Hospital / Medical environment ....................3.1.3 Aircraft ................................3.1.4 Vehicle ................................3.1.5 For Vehicles equipped with an airbag ..................3.1.6 Blasting areas ..............................
Page 3
6. Care and Maintenance .......................... 7. Installation 12–16 ..............................7.1 Mounting / Removal ........................... 7.2 SIM card ................................7.3 Antenna care and placement ......................14–17 7.4 Connections ............................7.4.1 Power interface ..........................7.4.2 RS-232 interface, screw terminal ..................7.4.3 RS-232 interface, 9-pin D-sub ....................
Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequental or indirect damages howsoever caused.
3. Safety General: Before using this unit, read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. Before installation, maintenance or modification work: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g.
3.1.2 Hospital / Medical environment Do not use the unit in a medical environment such as health care facities. Follow any regulations or rules that instruct you to not use the unit. Medical equipment may be sensitive to RF energy. If the unit is being used together with any medical devices (such as pacemakers, hearing aids, etc.) consult the physician and/or the manufacturer of the device to determine if it is adequately shielded from external RF energy.
3.1.8 RF energy The GD-01 US is a low power radio transmitter and receiver. When it is ON, it receives and also sends out radio frequency (RF) signals. Most modern electronic equipment is shielded from RF signals. However, certain elec- tronic equipment may not be shielded against the RF signals from your wireless unit.
• Consult the dealer or an experienced radio/TV technician for help. 3.3.2 Statement according to FCC part 15.21 Modifications not expressly approved by Westermo could void the user's authority to operate the equipment. 3.3.3. Statement according to FCC part 15.19 This device complies with Part 15 of the FCC Rules.
5. Specifications GSM services Circuit Switched Data Asynchronous transparent or non-transparent up to 14.4 kbit/s MNP2 error correction and V.42 bis data compression Fax group 3 (Class 1 and Class 2) 160 characters text or PDU Point to point (MT/MO) Cell broadcast GPRS GPRS Class 8, Class B...
Page 10
Mechanical Dimension (WxHxD) 55 x 100 x 128 mm Weight 0.3 kg Mounting 35 mm DIN-rail Degree of protection IP 20 (IEC 529) Isolation Power to all other 1,5 kV RMS @ 50Hz and 60 s duration Environmental Temperature, operating –25 to +50°C (–13 to +122°F) Temperature, storage –25 to +70°C (–13 to +158°F)
Always use the com- mand AT+CPOF or AT+CFUN=0 before disconnection the power if the SIM card is inserted. • If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. 6696-2230...
7. Installation 7.1 Mounting / Removal Before mounting or removing the unit: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). Hazardous voltage may occur within this unit when connected to power supply.
7.2 SIM card The SIM card is accessable under the lid on top of the unit.The SIM card is needed for full operation of the unit. Warning! Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap), before the lid on top of the unit is removed.
7.5 LED indicators PWR On Correct internal power No internal power Device switched off – Not ready Device switched on Connecting to network Flashing slowly Device switched on Idle mode (registered on network) Flashing rapidly Device switched on Transmission mode Blinking LED showing data received from the local RS-232 port No data received on the local RS-232 port...
7.6 Quick Start guide The serial interface default configuration is: … 115.2 kbit/s, 8 databits, no parity and 1 stop bit (please refer to AT+IPR and AT+ICF commands) … RTS / CTS flowcontrol enabled (please refer to AT+IFC command) … DTR signal must be active from the DTE (please refer to AT&Dn command) Follow the steps below to get the unit up and running as quickly as possible: …...
It can be used to link PLC:s, data loggers, security and surveillance systems or for data acquisition. The GSM services supported by the Westermo GD-01 US are Circuit Switched Data, Fax, SMS and GPRS. A data communication link can be established to another GSM modem, to an analogue modem or to a digital ISDN adapter.The protocol used when...
9. GSM network operators, subscriptions and services The GD-01 US support several services in the GSM network. In order to get the unit to work properly its important that the GSM service used in a specific application also is enabled on the subscription (the SIM card). When ordering a SIM card from a network operator its necessary to confirm that the specific service needed for the application is enabled before trying to set up the commu- nication link.
11. Related documents This installation manual is in related parts based on the following recommendations: … Westermo AT-command guide. … ETSI GSM 07.05: Digital cellular telecommunications system (Phase 2) Use of DTE-DCE interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) …...
Page 24
Westermo Teleindustri AB • SE-640 40 Stora Sundby, Sweden Phone +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.se Westermo Web site: www.westermo.com Subsidiaries Westermo Data Communications Ltd Westermo Data Communications S.A.R.L. Unit 14 Talisman Business Centre • Duncan Road 9 Chemin de Chilly 91160 CHAMPLAN Park Gate, Southampton •...