Quasi-Front Panel Operation Command Type; Status Condition Change Information Function; Command Receipt Confirmation Function - Mitsubishi Electric DX-TL5000E series Operation Manual

Digital recorder rs-232c communication capacity
Hide thumbs Also See for DX-TL5000E series:
Table of Contents

Advertisement

About command code table (continued)

Quasi-front panel operation command type

This system specifies operations from a PC as if operating the actual operation panel of the unit while viewing the output
picture. Each command is corresponded to the operation button of the unit.
Input confirmation format
Send commands as if operate the buttons, JOG dial and SHUTTLE ring on the operation panel. As a general rule, do not
send commands continuously, but send the next command after checking that the present command has been executed
and completed. After sending a command, the command execution result, error type, and command name can be
checked by the status returned from the unit. To check the actual execution, view the output screen of the unit on the
monitor screen.
Example) Playing back the recorded data in still frame playback.
Command
Replied status code
from unit to PC
from PC
#1
KKP0
#2
RC
EX,00KKP0
KKB1
#1
RC
#2
EX,00KKB1
KKB4
#1
RC
#2
EX,00KKB4
When using shuttle operation commands, be sure to send the shuttle center command after sending the operation
command. Otherwise, the shuttle operation will be kept until the shuttle center command is sent.
For control type commands such as recording, playback, etc., the interval between command transmission and
the actual operation (command execution) may take some time. To prevent the gap between operation and actual
execution, read the status after sending the command and check the actual operational transition, and then send
the next command.

Status condition change information function

Example) Notifying the status of the fan (stop of the fan).
Replied status code
from unit to PC
NTFY04,00050321140000
192168000100
#2
When you set "Communication Mode" in the <RS-232C Setting> to "Remote A," every status information is returned from
the unit. When "Remote B" is set, status information for the command is returned from the unit. When "Remote C" is set,
status information is not returned from the unit.

Command receipt confirmation function

After executing a received command, the error type for command execution is notified after the execution status, "EX."
Error type
Error description
00
Normal
01
Execution Error
02
Execution Unable Error
03
Incorrect command
04
Incorrect parameter
Indicates that a command equivalent to "press the POWER button" was sent.
Indicates that the unit has received a command.
#2
EX
: Indicates that a command has been executed.
00
: Indicates that the execution was successful. (Error type)
KKP0 : Indicates that the POWER button was operated.
Indicates that a command equivalent to "press the PLAY button" was sent.
Indicates that the unit has received a command.
EX
: Indicates that a command has been executed.
#2
00
: Indicates that the execution was successful. (Error type)
KKB1 : Indicates that the PLAY button was operated.
Indicates that a command equivalent to "press the PAUSE button" was sent.
Indicates that the unit has received a command.
#2
EX
: Indicates that a command has been executed.
00
: Indicates that the execution was successful. (Error type)
KKB4 : Indicates that the PAUSE button was operated.
NTFY
:Indicates the status condition change notification.
04
:Indicates the status of the fan.
00
:Indicates that the fan is stopped.
050321140000
:Indicates the occurence time and date (year/month/day/hour/minute/second).
192168000100
:Indicates the IP address of the unit.
Error type
Meaning
Meaning
Error description
05
Excuting the command
06
Not corresponding
4