Integra MZA-4.7 Instruction Manual page 17

Multizone amplifier
Hide thumbs Also See for MZA-4.7:
Table of Contents

Advertisement

RS232 Protocol—Continued
Data
Command
Standby
(01)
Mute
(02)
Source Selection
(03)
Volume
(04)
Bass
(05)
Treble
(06)
Balance
(07)
Send all parameters
(09)
Amplifier features
(0C)
Maximum Volume Limit
(0D)
Link Zone
(0F)
Volume Up
(11)
Volume Down
(12)
Zone Name
(1C)
Preamplifier Volume Mode
(1D)
Preset Selection
(1E)
Volume BCD Format
(26)
Notes:
■ Commands are used as notifications. If an amplifier is switched ON, it will notify the other devices on the control
bus by sending the Standby command (01). Any amplifiers with the same zone will take the notification as a
command and also switch ON.
■ When a command is sent to an amplifier it will first be transmitted on the control bus and then returned to the PC
(Home automation system). If an error occurs an error will be returned instead of the original command. The PC
(Home automation system) needs to ignore its command when it is returned.
Content
00 – Standby OFF
01 – Standby ON
04 – Toggle
00 – Mute
01 – Un-mute
02 – Toggle Mute
00 – S5
01 – S6
02 – S7
03 – S4
04 – S8
05 – S1
06 – S2
07 – S3
00 – A0 range
F4 – 0C (–12dB - +12dB)
F4 – 0C (–12dB - +12dB)
EC – 14 (Left –20dB - Right –20dB)
XX – value ignored
00 – Loudness disabled
01 – Loudness enabled
00 – A0 range
00 – 31 zone to be linked
FF – for no zone linking
XX – value ignored
XX – value ignored
Data field contains the ASCII string
00 – A0 range
FF = Independent mode.
All Zone function: Zone byte = FF
00 – Default : exit preset mode
01 – Force "Page Preset"
02 – Select Preset 1
03 – Select Preset 2
04 – Select Preset 3
05 – Select Preset 4
06 – Select Preset 5
07 – Select Preset 6
0 – 99 in BCD format same as Front Panel display
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents