Controller Termination - Integra MZA-4.7 Instruction Manual

Multizone amplifier
Hide thumbs Also See for MZA-4.7:
Table of Contents

Advertisement

Controller Termination

White/Blue
The recommended wiring and color scheme is shown in Fig 2.
Use the Standard 568-B color code for the CAT5E termination to the Controller – see Table 1. Although it is possible
to daisy chain controllers we recommend "home runs" of CAT5E cable with a maximum cable length of 200m.
Note: Some IR receivers have an Amplifier On indicator, their "On" terminal should be connected to the zone's AMP
ON output not to the controller interface ports "Data" terminal.
Orange and Green
White/Green
White/Orange
CAT5E cable used to
connect controllers
to MZA-4.7
Pin #
Wire Color
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
Fig 2
Keypad function
+12V DC
supply
0V
supply
IR
output
nc
Data
input
0V
supply
nc
nc
Table 1
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents