Overview Of The Info Mode; Viewing Cook Counter/Time Logs; Viewing The Fault Log - TurboChef i3 Service Manual

Rapid cook oven
Hide thumbs Also See for i3:
Table of Contents

Advertisement

Overview of the Info Mode

The Info Mode serves four main purposes:
1. To display oven information.
2. To provide access to Test Mode and additional
diagnostic tools for service technicians.
3. To turn oven options and features on/off.
4. To update oven settings.
To access the Info Mode, simply press the Info key
when the oven is either off or cooling down. To toggle
between screens 1 and 2, press the Up or Down key.
From screen 1 of the Info Mode (Figure 15):
- View the oven serial number
- View the oven software version
- View the menu part number and revision
- View the last temperature selected to cook
- View the electrical compartment temperature
- Scroll through counters (total cook time, magne-
tron time, total oven on time, and cumulative
cook count)
- View the operating voltage (North America
models only)
- Access the fault log
- Access service phone numbers
L1
S/N: i3-DXXXXXX
L2
SOFTWARE VERSION
L3
MENU P/N AND REV
L4
SP: 500F
EC TEMP: 84F
L5
Figure 15: Info Mode Screen 1
L1
TEST MODE
L2
SET OPTIONS
L3
SET LANGUAGE
L4
SET DATE/TIME 05/01/09 11:14:28
SOUND = = = = = = 7
L5
Figure 16: Info Mode Screen 2
R1
COUNTS SCROLL
R2
VAC = 240
INFO 1
R3
FAULT LOGS
SERVICE NUMBERS
R4
R5
R1
LOAD MENU
R2
F2 ALARM ON
INFO 2
R3
R4
R5
From screen 2 of the Info Mode (Figure 16):
- Access Test Mode
- Access the "Options" screen
- Set the language (not available on all models)
- Set the date/time
- Increase/decrease the tone volume (sound)
- Access the "Load Menu" screen
- Turn the F2 Alarm on or off (page 14 for details)

Viewing Cook Counter/Time Logs

From the Info Mode (Figure 15), press the R1
soft key:
- Once to display total cook time.
- Twice to display total magnetron time.
- Three times to display total "oven on" time.
- Four times to display a cumulative cook count.

Viewing the Fault Log

Figures 17-18. For more information on faults,
see pages 35-36. To zero the fault counters, select
Clear All.
From the Info Mode (Figure 15), press the R3 soft
key to view the fault log (Figure 17). To view time
stamps of each fault occurrence (Figure 18), press the
soft key adjacent to the fault code.
L1
FAULT LOG
F1: BLOWER
8
L2
F2: LOW TEMP
0
L3
F3: MAG C LOW
0
L4
F4: MONITOR
0
F5: MAG OT
0
L5
Figure 17: Fault Log
L1
F1 FAULT DETAIL
12/04/09 20:18
L2
09/26/09 17:42
07/18/09 14:35
07/15/09 08:36
L3
07/14/09 22:07
07/14/09 13:54
L4
07/14/09 05:22
SCREEN 1 OF 13
L5
Figure 18: Fault Time Stamp Detail
R1
F6: EC OT
0
R2
F7: RTD OPEN
0
R3
F8: HX RISE LOW
0
F9: CC OT
0
R4
<CLEAR ALL>
R5
R1
R2
R3
R4
R5
MORE
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

I5

Table of Contents