D-04: Aux RY1 MIN. ON time
Use Constant D-04 is to set the minimum time that the relay can remain active.
The minimum time is set to avoid the difference of the values set in D-02 and
D-03 is so small to cause the damage on the relay due to the high frequency of
relay action between ON and OFF.
E-01: Set Aux Relay 2 Mode
E-02: Aux RY2 ON Condition
E-03: Aux RY2 OFF Condition
E-04: Aux RY2 MIN. ON time
The functions and the settings of Auxiliary Relay 2 are exactly the same as those
of Auxiliary Relay 1 so please refer to above Group D, Auxiliary Relay 1
description.
F-01: Parallel MODE
Use Constant F-01 to set up OPTI-Solar SC MPPT Series Network. Each
OPTI-Solar SC MPPT Series in parallel requires a mode and address entry.
The Mode choices are:
e S
i t t
g n
Standalone
Master
Slave
Used when there is only one OPTI-Solar SC MPPT Series
with a Remote Display connected.
Used to assign the network master (this is the OPTI-Solar SC
MPPT Seriesthat connects to the shunt).
Assigns up to 15 additional OPTI-Solar SC MPPT Series slave
units.The first OPTI-Solar SC MPPT Series is assigned as
master and the rest of units in network are slaves. The network
address will be assigned to each slave unit in F-02.
5-12
Group E
Auxiliary Relay 2
Group F
Parallel Setup