NOTE 3 (B-09, B-10, B-11, B-12)
These constants are only displayed if Flooded is selected as battery type (B-02).
NOTE 4 (C-02, C-03, C-04, C-05)
C-02 is only displayed if P and O or Scan and Hold is selected as MPPT Type (C-01).
C-03 and C-04 are only displayed if Percentage is selected as MPPT Type (C-01).
C-05 is only displayed if Hold Input V is selected as MPPT Type (C-01).
NOTE 5 (U-16, F-02)
U-16 and F-02 are only displayed if Slave is selected as OPTI-Solar Network MODE
(F-01).
NOTE 6 (B-04, B-05, C-05, O-04)
The factory settings of the listed constants are dependent on the different model
numbers.
Constant
B-04
Set Battery Capacity
B-05
Bat. MAX Charge Amps
C-05
Set Hold Input Volts
O-04
LCD Display
Model Number
4-7
SC-80 MPPT
Factory Setting
1600 Ahr
80A
140Vdc
SC-80 MPPT
SC-160X MPPT
Factory Setting
3200Ahr
160A
240Vdc
SC-160X MPPT