B-07: Set Absorption Time
Use Constant B-07 to adjust the length of Absorption time. The factory setting is
2 hours (displayed as 02:00).
B-08: Set Float Voltage
Use Constant B-08 to adjust the Float voltages. The default set values are based
on the battery type and capacity selected. It is not advisable to change default
settings unless advised by the battery manufacturer or supplier.
Battery Type
FLOODED
AGM
GEL
¡ °
The above values are based on 12V system. The values x 2 are for 24V system;
the values x 3 are for 36V system and the values x 4 are for 48V system.
B-09: Set Equalize Voltage
This constant is only displayed if Flooded is selected as battery type (B-02). Use
Constant B-09 to select the Equalize voltages. The default values are based on
the battery voltage and capacity selected. It is not recommended to change
default settings unless advised so by the battery manufacturer or supplier.
Battery Type
FLOODED
B-10: Set MAX EQU. Time
This constant is only displayed if Flooded is selected as battery type (B-02). Use
Constant B-10 to select the time of equalization time. The factory setting is 2
hours (displayed as 02:00).
Float Volts Range
12.9V~14.2V
12.8V~14.2V
12.8V~14.1V
Battery
Equalization Volts Range
Voltage
12V
14.7V~16.4V
24V
29.4V~32.8 V
36V
44.1V~49.2V
48V
58.8V~65.6V
5-7
Factory
Setting
13.8V
13.2V
13.5V
Factory
Setting
15.6V
31.2V
46.8V
62.4V