Led Indicators - opti-solar SC-50 Installation And Operation Manual

Opti-solar sc mppt series solar charge controller
Table of Contents

Advertisement

PB4
PB5
PB6
PB7
PB8

4 LED Indicators

Flashing/
LEDs
Solid
FAULT
Solid Red
Flashing
EQUAL
Orange
Flashing
CHARGE
Green
READY
Solid Green
LCD Meter
1 LCD Meter of 20 x 2 characters is built in each OPTI-Solar SC MPPT Series unit.
Reset key to reset the fault.
ESC key to return to the last selection level.
Quick function key to the Main Menu: Data Log
Quick function key to the Main Menu: Programming
Quick function key to the Main Menu: Initialize
Quick function key to the Main Menu: Operation
Read the LCD meter for fault condition displayed.
4 fault conditions could be displayed as follows:
ERROR!!!
High Input Voltage
ERROR!!!
Parallel COM Failed
OPTI-Solar SC MPPT Series unit is in equalization mode.
Refer to constant. B-09~B-12 for the setting details.
OPTI-Solar SC MPPT Series unit is in charge mode.
This indicates that it is functioning properly.
When the voltage from the PV array is first received, the
OPTI-Solar SC MPPT Series is in standby mode to charge.
2-2
Description
ERROR!!!
OPTI-Solar Over-Temp.
ERROR!!!
Battery Over-Temp.