opti-solar SC-50 Installation And Operation Manual

Opti-solar sc mppt series solar charge controller

Advertisement

Quick Links

w w w . o p t i - s o l a r . c o m
OPTI-Solar SC MPPT Series
SOLAR CHARGE CONTROLLER
SC-50 / SC-80 / SC-80X / SC-160X MPPT
Installation and Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for opti-solar SC-50

  • Page 1 . o p t i - s o l a r . c o m OPTI-Solar SC MPPT Series SOLAR CHARGE CONTROLLER SC-50 / SC-80 / SC-80X / SC-160X MPPT Installation and Operation Manual...
  • Page 2: Table Of Contents

    CONTENTS Introduction ..........................¢ ¼ Feature ............................IV Specification..........................VI Dimension ...........................VII Chapter 1 Installation........................ 1-1 1.1 Loads Requirement..................1-1 1.2 Battery Voltage System ................... 1-1 1.3 PV Array Voltage..................... 1-1 1.4 Maximum Voc ....................1-1 1.5 Shunt (BCS)...................... 1-2 1.6 Battery Temperature Sensor (BTS-3)............1-2 1.7 Battery Voltage Sensing (BVS) ...............
  • Page 3 G Group: Data Log....................4-5 Chapter 5 Programming Constants ..................5-1 U Group: Operation ....................5-1 A Group: Initialize....................5-4 B Group: Battery Setup................... 5-5 C Group: MPPT Setup.................... 5-8 D Group: Auxiliary Relay 1 ..................5-9 E Group: Auxiliary Relay 2 .................. 5-12 F Group: Parallel Setup ..................
  • Page 4: Introduction

    The input PV array of the SC-50 MPPT and SC -80 MPPT may be wired in the range of 16~112Vdc nominal and the input PV array of the SC -80X and SC -160X may be wired in the range of 16~192Vdc nominal. The output battery voltage is accepted from 12 to 48Vdc nominal.
  • Page 5 2/3/4-stage charging with adjustable set points for all parameters. Wire the PV modules in series up to 112VDC normal (140VDC Max) for SC-50 Series, SC-80 Series and 192VDC normal (240VDC Ma x) for SC-80X Series, SC-160X Series. Easy stacking of up to 16 units in parallel for high currents.
  • Page 6: Specification

    Specification Model No. SC-50 MPPT SC-80 MPPT SC-80X MPPT Maximum output current (Continuous at up 50 50 Amps 80 Amps 80 Amps ambient temperature) e t t Max PV Input Current 40 Amps 70 Amps 70 Amps 16~112VDC Operating 16~192VDC Operating...
  • Page 7 Dimension for SC-50 MPPT Unit: mm Fig-1...
  • Page 8 Dimension for SC-80 MPPT Dimension for SC-80X MPPT Unit: mm Fig-2 VIII...
  • Page 9 Dimension for SC-160X MPPT Unit: mm Fig-3...
  • Page 10: Chapter 1 Installation

    24V battery system but it draws only 2 amps at 48V system. 1.3 PV Array Voltage As the OPTI-Solar SC MPPT Series is a smart DC to DC converter design, the specification of a PV array is much like sizing a grid tie inverter. Installers choose the max.
  • Page 11: Shunt (Bcs)

    1.5 Shunt (BCS) The Shunt is an optional component and it is required for the OPTI-Solar SC MPPT Series to achieve to the optimal operation levels and it functions as a hub for connect- ing measurement sensors. The main purpose of the shunt is to allow the OPTI-Solar SC MPPT Series to measure current drawing into and out of the battery.
  • Page 12 Fig-4...
  • Page 13: Installation Steps

    4. Connect the BAT+ terminal of the OPTI-Solar SC MPPT Series to the DC breaker. 5. Connect the GND terminal (next to BAT+) of the OPTI-Solar SC MPPT Series to the Shunt. 6. Install a 90 Amp rated DC breaker and connect it to the PV array + and also to the PV+ terminal of the SC-80.
  • Page 14: Chapter 2 Wiring

    Chapter 2 Wiring 2.1 Front Panel Display LCD Meter Indicator PB 3 PB 2 PB 1 PB 4 PB 8 PB 7 PB 6 PB 5 8 Push Buttons Data write-in key UP key to increment setting values. UP key to go to the next selection or constant. DOWN key to decrement setting values.
  • Page 15: Led Indicators

    When the voltage from the PV array is first received, the READY Solid Green OPTI-Solar SC MPPT Series is in standby mode to charge. LCD Meter 1 LCD Meter of 20 x 2 characters is built in each OPTI-Solar SC MPPT Series unit.
  • Page 16: Control Terminal Connection

    Connecting terminal for Battery Temperature Sensor Positive F BCS+ Connecting terminal for optional Shunt Positive G Parallel IN Connections for parallel input from last OPTI-Solar SC MPPT Series H Parallel OUT Connections for parallel output I Remote Connecting terminal to Remote Panel Display...
  • Page 17 J MA1 Connecting terminal for the contact A of auxiliary 1 K MC1 Connecting terminal for the common contact of auxiliary 1 L MB1 Connecting terminal for the contact B of auxiliary 1 M MA2 Connecting terminal for the contact A of auxiliary 2 N MC2 Connecting terminal for the common contact of auxiliary 2 O MB2...
  • Page 18: Parallel Connection

    2.3 Parallel Connection The parallel connection of OPTI-Solar SC MPPT Series can be up to 16 units (1 Master and 15 Slaves) and in the parallel system, there is only one Shunt which needs to be connected to the Master unit to measure the total accumulated current.
  • Page 19: Structure Of User Constants

    Chapter 3 User Constants 3.1 The following is the structure of user constants. U-12 Battery SOC U-13 Battery Current U-14 Battery Amp Hours U-15 Battery Temperature U-16 Parallel COMM Status U-17 Serial Number i t i A-02 Init Parameters A-03 Password 1 A-04 Password 2 B-02 Set Battery Type B-04 Set Battery Capacity...
  • Page 20: Initialization Stage Flow Chart

    3. 2 The following is the “Initialization Stage Flow Chart”. OTPI-Solar SC-80 MPPT V0.9311...
  • Page 21 Set OPTI-Solar Date O-03= MM/DD/YY SAVE: If SAVE is selected by pressing key, the controller will save the entered settings and operate with them RCLL (RECALL): Pressing key will return to the last setting prior to entering setup. DFLT (DEFAULT): If DFLT is selected by pressing...
  • Page 22: Operation Stage Flow Chart

    3.3 The following is the “Operation Stage Flow Chart”. Main Menu Main Menu-Operation Menu Constants...
  • Page 23 Main Menu-Initialize Menu Constants Constants Edit Data Enter Main Menu-Programming Group B Menu Group Constants Constants Edit Data Enter...
  • Page 24 Main Menu-Programming Group C Menu Group Constants Constants Edit Data Enter Main Menu-Programming Group D, D-01= ON or OFF Menu Group Constants Constants Edit Data Enter...
  • Page 25 Main Menu-Programming Group D, Auxiliary 1 ON/OFF Condition Setting Menu Group Constants Constants Edit Data Enter *** Main Menu *** Operation ¡ ¶ *** Main Menu *** Initialize ¡ ¶ DATA ENTER Group B *** Main Menu *** Battery Setup Programming ¡...
  • Page 26 Main Menu-Programming Group E, Auxiliary 2 ON/OFF Condition Setting Menu Group Constants Constants Edit Data Enter...
  • Page 27 Main Menu-Programming Group F Menu Group Constants Constants Edit Data Enter...
  • Page 28 Main Menu-Programming Group O Menu Group Constants Constants Edit Data Enter 3-10...
  • Page 29 Main Menu-Data Log Menu Constants Constants Edit Data Enter 3-11...
  • Page 30: Chapter 4 Constants List

    Chapter 4 Constant List Factory Main Menu Group Constant LCD Display Range Unit Remark Page Setting =xxx.xV xxx.xAmps 0.1V U-00 =xxx.xV xxx.xAmps 0.1A U-01 Input Voltage 0.1V U-02 Input Current 0.1A U-03 Output Voltage 0.1V U-04 Output Current 0.1A 1kWHr U-05 EnergyHarvestToday 1 1AHr...
  • Page 31 Factory Main Menu Group Constant LCD Display Range Unit Remark Page Setting ¢ w B-05 BAT. MAX Charge Amps 0~80/0~160 NOTE 6 FLOOD- 13.9~15.2 0.1V 14.6 Set Absorption B-06 Volts 13.7~15.1 0.1V 14.1 13.6~15.1 0.1V 14.1 0~ 99 Hr B-07 Set Absorption Time 1 Min 2 Hr...
  • Page 32: D Group: Auxiliary Relay 1

    Factory Main Menu Group Constant LCD Display Range Unit Remark Page Setting Auxiliary Relay 1 OFF, ON, Solar Voltage, Output Volts, Battery Volts, OUT Current, D-01 Set Aux Relay 1 Mode BATT Current, Temp. Battery Temp. Time Battery SOC, Output Volts Aux RY1 ON Condition See Below 5-10...
  • Page 33: E Group: Auxiliary Relay 2

    Factory Main Menu Group Constant LCD Display Range Unit Remark Page Setting 00~23 Hr When D-01= Time 1 Min 5-11 00~59 Min D-03 When D-01=Battery SOC 0~100 5-11 0~23 Hr, D-04 Aux RY1 MIN. ON time 1 Min 5-11 0~59Min Auxiliary Relay 2 OFF, ON, Solar Voltage,...
  • Page 34: F Group: Parallel Setup

    Factory Main Menu Group Constant LCD Display Range Unit Remark Page Setting When E-01=OUT Current 0~80/0~160 5-12 When E-01=BATT Current -500~500 5-12 When E-01=Temp. -20~100 5-12 E-03 When E-01=Battery Temp. -20~100 5-12 00~23 Hr When E-01=Time 1 Min 5-12 00~59 Min When E-01=Battery SOC 0~100 5-12...
  • Page 35 Today’s Data Today’s ¢ w Data Log G-09 Clear Energy Harvest 5-16 Logged Data Data NOTE 1 (U-12, U-13, U-14, U-15) Battery SOC, Battery Current and Battery Amp Hours will only be visible when terminal BVS (Battery Voltage Sensing) is connected to the battery and will only be active when using an optional 50mv/500amp external shunt.
  • Page 36 C-03 and C-04 are only displayed if Percentage is selected as MPPT Type (C-01). C-05 is only displayed if Hold Input V is selected as MPPT Type (C-01). NOTE 5 (U-16, F-02) U-16 and F-02 are only displayed if Slave is selected as OPTI-Solar Network MODE (F-01). NOTE 6 (B-04, B-05, C-05, O-04) The factory settings of the listed constants are dependent on the different model numbers.
  • Page 37: Chapter 5 Programming Constants

    OUT=xxx.xV xxx.xAmps Use Constant U-00 to monitor the power coming in from the PV array in Volts and Amps. The second line displays the power going out of the OPTI-Solar MPPT, it also displays in Volts and Amps. In most installations there will be a difference between incoming volts and outgoing volts.
  • Page 38 This screen displays how much time the charger was in Float mode “Today” in Hour:Minute. U-08: Stage of Charger This screen displays the charging stage of OPTI-Solar MPPT. The possible values are Charger Off, Charger Start, BULK Stage, ABSORP Stage, FLOAT Stage, Charger MPPT, Charger Stop, EQUALZ Stage.
  • Page 39 U-16 is only displayed when Slave is selected as OPTI-Solar Network MODE (F-01). When the communication is successful, the screen displays SLAVE UNIT. When the communication fails, then screen displays NETWORK ERROR. U-17: Serial Number This screen displays the unit serial number. It is useful when contacting OPTI-Solar MPPT support.
  • Page 40 *** Main Menu*** Initialize A-01: Access Level Use Constant A-01 to select the user constant access level. This level determines which user constants can be changed and displayed. Settings: A-01=Constant Set (Factory Setting) This setting allows all user constants to be changed and displayed. A-01=Operation Only This setting allows the “Operation”...
  • Page 41: B Group: Battery Setup

    Battery Setup B-01: Set Battery Voltage During initialization of OPTI-Solar SC MPPT Series, it will detect and ask the installer to confirm the battery voltage found is co rrect. In almost all circumstance the OPTI-Solar SC MPPT Series will correctly detect battery voltage.
  • Page 42 The above values are based on 12V system. The values x 2 are for 24V system; the values x 3 are for 36V system and the values x 4 are for 48V system. OPTI-Solar SC MPPT Series will charge at the Absorption voltage and at the length of time before switching to float mode.
  • Page 43 B-07: Set Absorption Time Use Constant B-07 to adjust the length of Absorption time. The factory setting is 2 hours (displayed as 02:00). B-08: Set Float Voltage Use Constant B-08 to adjust the Float voltages. The default set values are based on the battery type and capacity selected.
  • Page 44: C Group: Mppt Setup

    Equalizing blinks in return. CHARGE displays charging current. Finally, the remaining time for equalization charge is counted down. WARNING: Before the manual equalization is selected, OPTI-Solar SC MPPT Series should be connected to Battery Temperature Sensor (BTS-3). If it is not connected to BTS-3, “Warning, Bat.
  • Page 45: D Group: Auxiliary Relay 1

    Type (C-01). The scan frequency is settable from 1 minute to 4 hours and the factory setting is 1 hour. Press the UP and DOWN key to increase or decrease the length of time. P and O (Perturb and Observe) will run a full scan at the set time interval (frequency) and then do P and O scans at shorter intervals in between.
  • Page 46 functions will be added in the future. Use Constant D-01 to select the Auxiliary Relay 1 mode and what it is based on. Auxiliary Relay 1 Mode includes OFF, ON, Solar Voltage, Output Voltage, Battery Voltage (only displayed and active when terminal BVS is connected to the battery), Output Current, Battery Current (only active when terminal BCS is connected with a Shunt 50mV, 500Amp), Temperature, Battery Temperature (only active when terminal BTS is connected with a Battery...
  • Page 47 00~23 Hr When D-01=Time 1 Min 00~59 Min 0~100% When D-01=Battery SOC Battery SOC is only active when terminal BCS is connected with a Shunt 50mV, 500Amp. D-03: Aux RY1 OFF Condition According to 9 selectable modes in D-01, use Constant D-03 to set the condition to activate the Auxiliary Relay 1 to be OFF.
  • Page 48: E Group: Auxiliary Relay 2

    Group F Parallel Setup F-01: Parallel MODE Use Constant F-01 to set up OPTI-Solar SC MPPT Series Network. Each OPTI-Solar SC MPPT Series in parallel requires a mode and address entry. The Mode choices are: i t t Used when there is only one OPTI-Solar SC MPPT Series Standalone with a Remote Display connected.
  • Page 49: O Group: Operator

    F-02: Parallel Addr A OPTI-Solar SC MPPT Series assigned as Master or Standalone is always addressed 01 automatically so the address assignment in F-02 is only available for the slave units. The maximum slave address number is 16 and the factory setting is 2.
  • Page 50: G Group: Data Log

    When FAN ON is selected, the fan test is conducted as the O-06 screen remains. Once the screen leaves O-06, it will stop the test running. O-07: Software Version The software version displayed is important and useful when contacting OPTI-Solar MPPT support. O-08: ***Bootloader*** This is the Bootloader initiation display.
  • Page 51 G-03: Set Day LOG# (1-90) Use G-03 to set the Day Log number to display the energy harvested from PV array (shown in G-04 and G-05) by OPTI-Solar SC MPPT Series over a period of time. If it is selected as #2 displays past power production since the last power cycle (or up to 90 days previous) along with the date of day before the current date.
  • Page 52 Press ENTER key and use UP and DOWN keys to select between Today’s Data and Logged Data and then press ENTER key again to clear the selected data. 5-16...
  • Page 53: Chapter 6 Trouble Shooting

    High Input Voltage for SC-160 MPPT, the battery rated voltage range. charging stops. Place the OPTI-Solar SC The ambient temperature is too MPPT Series unit in a ERROR!!! high and it causes the over cool and well-ventilated Over-Temp.