INSTALL THE HOOD (HORIZONTALLY DUCTED HOODS ONLY)
1. DO NOT REMOVE the protective plastic
film covering the decorative flues at this
time.
LOWER FLUE
MOUNTING
BRACKET
8¼"
MAX.
2. Make sure there will be adequate
clearance between top of hood and
lower flue mounting bracket for ductwork.
Elbow must be located below lower flue
mounting bracket.
3. Align the hood and center it above the
hood mounting bracket. Gently lower the
hood until it securely engages the bracket.
INSIDE
BACK
OF
HOOD
SIDE VIEW
HOLE LOCATIONS
4. If a framing member is not present: With
the hood hanging in place, drill through
both holes located in the inside lower back
of hood using a 5/16" drill bit. Insert the
included drywall anchors into the drilled
holes (one for each hole).
5. Install (2) washers and (2) #8 x 1½"
mounting screws through the back of the
hood and into the drywall anchors. Verify
that the hood is centered and leveled.
Tighten all screws completely.
6. Measure and
install 6" round
metal ductwork
to roof cap or
wall cap and 90
elbow over duct
collar on hood.
Use duct tape to
make all joints
secure and air
tight.
7. Plug hood power
cord into the
outlet.
8. Remove the upper
flue from inside
the lower flue.
Install the lower
flue bracket to the
lower flue using
(2) flue bracket
screws (#8 x
3/8"). Ensure
that the bracket
is positioned inside of the lower flue flanges - with the
slots on top. Carefully replace the upper flue inside the
lower flue. Remove protective plastic film covering the
lower flue only.
MOTOR/
9. Carefully place both flues into the recessed area of
BLOWER
hood top.
ASSEMBLY
10. Slide the upper
flue upward until it
is aligned with its
upper flue mounting
bracket. The bracket
Ø5/16"
should be inside
TYP.
the flue. Secure the
upper flue to the
upper flue mounting
bracket using (2) #8
x 3/8" mounting
screws.
11. Remove protective
plastic film covering
the upper flue and
the hood.
12. Reinstall grease filter
by aligning rear filter tab with slot in the hood, push in
the metal latch tab, push filter into position and release.
Make sure filter is securely engaged after installation.
6" ROUND
ELBOW
o
UPPER FLUE MOUNTING
BRACKET - FRONT VIEW
9
LOWER FLUE
MOUNTING BRACKET
LOWER FLUE
UPPER
FLUE