Kenmore 233.5992 Series Use & Care / Installation Manual

Kenmore 233.5992 Series Use & Care / Installation Manual

Range hood

Advertisement

Available languages

Available languages

Use & Care / Installation Manual
Manual de Uso y Cuidado / Instalación
English / Español
Models/Modelos 233.5992*, 5993*
Kenmore
®

Range Hood

Campana de cocina
*
= color number, número de color
P/N 99528329B
Sears Brands Management Corporation,
Hoffman Estates, IL 60179 USA
www.kenmore.com
www.sears.com

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore 233.5992 Series

  • Page 1: Range Hood

    Use & Care / Installation Manual Manual de Uso y Cuidado / Instalación English / Español Models/Modelos 233.5992*, 5993* Kenmore ® Range Hood Campana de cocina = color number, número de color P/N 99528329B Sears Brands Management Corporation, Hoffman Estates, IL 60179 USA www.kenmore.com...
  • Page 2: Table Of Contents

    READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SECTION ................ PAGE SECTION ................ PAGE Safety Instructions ..............2 Equivalent Duct Length Chart ..........5 Warranty ................3 Prepare The Hood Location ..........6 Operation ................3 Prepare The Hood .............7, 8 Cleaning ................4 Connect The Wiring .............9 Parts Included With Hood ..........
  • Page 3: Operation

    OPERATION KENMORE LIMITED WARRANTY When this appliance is installed, operated and CONTROLS maintained according to all supplied instructions, the following warranty coverage applies. To arrange for warranty service, call 1-800-4-MY- HOME ® (1-800-469-4663). • For one year from the date of purchase, any...
  • Page 4: Cleaning

    PARTS NOT INCLUDED WITH HOOD* • Let plaster dust or any other construction residues reach the hood. During construction/renovation, cover the range hood to make sure no dust sticks to the stainless steel surface. NON-DUCT KIT - KENMORE PART NO. 59921 Avoid: When choosing a detergent • Any cleaners that contain bleach will attack stainless steel • Any products containing: chloride, fluoride, iodide, bromide NON-DUCTED will deteriorate surfaces rapidly.
  • Page 5: Equivalent Duct Length Chart

    3¼-in. x 10-in. Right-angle 6-in. Round duct) Equivalent Long Transition length 30 ft. Eave Elbow Equivalent length (7-ft. w/o damper) Equivalent 5.5 ft. length 15 ft. Kenmore Model Ducting Accessories are available by calling 1-800-4-MY-HOME ® Broan Model Ducting Accessories are available by calling 1-800-558-1711.
  • Page 6 INSTALL THE DUCTWORK WARNING ROOF CAP To reduce the risk of fire, use only metal ductwork. 1. Decide where the ductwork will run between the ROUND ELBOW 6” hood and the outside. ROUND DUCT WALL CAP 2. A straight, short duct run will allow the hood to perform most efficiently.
  • Page 7 INSTALL UPPER FLUE MOUNTING BRACKET 1. If a framing member is not present, drill two Center of installation Ceiling 5 ⁄ 1 6” diameter holes where shown. Insert dry- wall anchors into the holes. Recommended ⁄ ” distance 2. Center the bracket over the hood location and between flush with the ceiling.
  • Page 8 INSTALL CURVED GLASS PLATE 1. Place range hood body on its back, with controls facing up. Place cardboard under hood to protect M4 X 1-IN. countertop or table finish. SCREWS (BLACK) 2. Position the curved plate glass over the range hood body as shown.
  • Page 9: Install The Hood

    INSTALL THE HOOD (HORIZONTALLY DUCTED HOODS ONLY) 1. DO NOT REMOVE the protective plastic 6. Measure and 6” ROUND film covering the decorative flues at this install 6” round ELBOW time. metal ductwork to roof cap or wall cap and 90 LOWER FLUE elbow over duct MOUNTING...
  • Page 10 INSTALL THE HOOD (VERTICALLY DUCTED HOODS ONLY) 1. DO NOT REMOVE the protective plastic film LOWER FLUE covering the decorative flues at this time. MOUNTING BRACKET 2. Align the hood and center it above the hood mounting bracket. Gently lower the hood until it securely engages the bracket.
  • Page 11 INSTALL THE HOOD (NON-DUCTED HOODS ONLY) Note: Purchase Non-Duct Kit, 13. If a framing Kenmore part number 59921. member is not present: 1. CAUTION: Use only expandable INSIDE With the aluminum duct provided with non-duct BACK hood hanging kit. in place, drill MOTOR/ 2.
  • Page 12: Service Parts

    INSTALL FLUE EXTENSION FOR 10-FT. CEILINGS Note: 10-ft. ceilings require the purchase of a flue extension, Kenmore part number 59920. 1. Discard the upper flue (supplied with the hood) and replace it with the longer flue section. 2. Follow all steps shown in the section “INSTALL THE HOOD” for horizontal, vertical and non-ducted installations. SERVICE PARTS Models 233.5992*, 5993* * = color number KEY PART NO. DESCRIPTION QTY. 99527669 Decorative Upper and Lower Flues...
  • Page 13 LEA Y CONSERVE ESTAS INSTRUCCIONES ÍNDICE SECCIÓN ..............PÁGINA SECCIÓN ..............PÁGINA Instrucciones de seguridad ..........13 Cuadro de equivalencias en la longitud de los ductos ..16 Garantía ................14 Prepare la ubicación de la campana ......17 Funcionamiento ..............14 Prepare la campana ............
  • Page 14 FUNCIONAMIENTO GARANTÍA LIMITADA DE KENMORE Cuando este electrodoméstico es instalado, se hace CONTROLES funcionar y mantiene de acuerdo con todas las instrucciones incluidas, aplica la cobertura de la siguiente garantía. Para pedir servicio de garantía, llame al 1-800-4-MY-HOME ® (1-800-469-4663).
  • Page 15 PIEZAS NO INCLUIDAS CON LA CAMPANA* algún otro residuo de la construcción. Durante la construcción o la renovación, cubra la campana para estar seguro de que el polvo no se pegue a la superficie de acero inoxidable. JUEGO SIN CONDUCTOS – PIEZA KENMORE N. 59921 Evite: Al elegir un detergente • Todo limpiador que contenga blanqueador, pues atacará al FILTRO DE acero inoxidable.
  • Page 16 (8.25 x 25.4 cm) de 7 pulg. (17.8 cm) o de (8.25 x 25.4 cm). a 6 pulg. (15 cm). 3 ¼ x 10 pulg. (8.25 x 25.4 cm). Longitud Longitud equivalente Longitud equivalente de equivalente de de 5.5 pies (1.68 m). 30 pies (9.15 m) (7 pies [2.1 m] 15 pies (4.6 m). sin regulador de tiro). Los accesorios para conductos modelo Kenmore están disponibles llamando al 1-800-4-MY-HOME ® Los accesorios para conductos modelo Broan están disponibles llamando al 1-800-558-1711.
  • Page 17 INSTALACIÓN DEL SISTEMA DE CONDUCTOS ADVERTENCIA TAPA DE TECHO Para reducir el riesgo de incendio, use solamente conductos metálicos. CONDUCTO CODO REDONDO REDONDO DE 1. Decida dónde instalará el conducto entre la campana y . (15 PULG TAPA DE PARED el exterior.
  • Page 18 INSTALACIÓN DEL SOPORTE DE MONTAJE DEL TUBO DE HUMOS SUPERIOR 1. Si falta una pieza del bastidor, perfore dos Centro de la instalación Cielo raso orificios de 5 ⁄ 16 pulg. de diámetro donde se muestra. Inserte los taquetes para placa de Distancia ⁄...
  • Page 19 INSTALE LA PLACA DE VIDRIO CURVO 1. Coloque el cuerpo de la campana sobre la parte (4) posterior, con los controles hacia arriba. Coloque TORNILLOS un cartón debajo de la campana para proteger la M4 X 1 PULG. cubierta o el acabado de la mesa. (NEGROS) 2.
  • Page 20 INSTALE LA CAMPANA (SOLO PARA CAMPANAS CON CONDUCTOS HORIZONTALES) 1. En este momento NO QUITE la película 6. Mida e instale los CODO de plástico protector que cubre el tubo de conductos metálicos REDONDO humos decorativo. redondos de 6 pulg. DE 6 PULG.
  • Page 21 INSTALE LA CAMPANA (SOLO PARA CAMPANAS CON CONDUCTOS VERTICALES) 1. En este momento NO QUITE la película de plástico SOPORTE DE MONTAJE DEL protector que cubre el tubo de humos decorativo. TUBO DE HUMOS INFERIOR 2. Alinee la campana y céntrela arriba del soporte de montaje de la campana.
  • Page 22 INSTALE LA CAMPANA (SOLO PARA CAMPANAS SIN CONDUCTOS) Nota: Compre el juego sin conductos, 13. Si falta una número de pieza Kenmore 59921. pieza del PARTE bastidor: Con 1. PRECAUCIÓN: Utilice únicamente INTERIOR la campana el conducto de aluminio expansible colgada en su TRASERA incluido con el juego sin conductos.
  • Page 23 INSTALE LA EXTENSIÓN DEL TUBO DE HUMOS PARA CIELOS RASOS DE 10 PIES (3 M) Nota: Los cielos rasos de 10 pies (3 m) requieren la compra de una extensión para el tubo de humos, número de pieza Kenmore 59920. 1. Deseche el tubo de humos superior (incluido con la campana) y reemplácelo con la sección de tubo de humos más larga.

This manual is also suitable for:

233.5993 series

Table of Contents