BDV7 Series Direct Vent Gas Fireplace

Blot AutoMAtIC theRMoStAt BloWeR

Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing the
fireplace. Wire with minimum 60° C wire in accordance
with prevailing codes.

FK-12 MANuAl BloWeR

1. This must be done before framing the fireplace. When
installing the FK-12 blower, a wall switch control must
be installed to control the blower.
2. The fireplace power supply is wired through the blower
wall switch and then brought to the fireplace junction
box.
3. The jumper clip on the plug receptacle must be re-
moved. Figure 56. Use needlenose pliers to break off
the jumper clip.
Figure 56 -
FK-12 Blower wiring Diagram
36
Receptacle 
WHITE
BLACK
Speed Control 
FP2675
BLOT blower wiring
Plug into switch outlet
FK-12 Blower
oPtIoNAl FAN BloWeR SySteMS
Junction 
Box
WHITE
BLACK
Figure 55 -
BLOT Blower Wiring Diagram
Jumper clip on plug
receptacle must be
removed on power side to
make outlet switchable
Junction Box
FP2676
FK12 wiring
120VAC
BLACK
GREEN
BLACK
Blower
Wall Switch
Red
Black
Black (live)
Green (ground)
White (neutral)
FP2676
FP2675
20301836