Match Lighting Instructions; Blower Operation - Monessen Hearth VCF Series Installation & Operating Instructions Manual

Vent free fireplace system
Table of Contents

Advertisement

VFC Vent Free Fireplace System
1. Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).
2. Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo
button, light a match and hold the flame to the end of the pilot and ignite the pilot.
3. After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot
access.
4. Call a qualified service technician for repair or replacement of the piezo ignitor.

BLOWER OPERATION

Figure 37. Location of Blower Control
Locate the blower control by opening control access door.
The variable controlled thermostat blower is located to the
right of heater controls. .
In the OFF position, the blower will not operate; however,
the heater can be operated without the blower being ON. In
the ON (AUTO) position, the blower will start when the ther-
mostat senses a sufficient increase in firebox temperature.

MATCH LIGHTING INSTRUCTIONS

Blower Control
Monessen • VFC 24/32 Owner Manual • 20308011 • Rev J • 01/22
OPERATING INSTRUCTIONS
NOTE: Your gas logs and blower will not turn on and off
at the same time. The gas logs may burn several minutes
before blower turns on. The blower will continue to run for
several minutes after the flames have turned off.