Optional Fan/Blower Systems; Blotbldvsc - Monessen Hearth WDV500 Installation And Operating Instructions Manual

Wdv wideview direct vent gas fireplace
Table of Contents

Advertisement

OptIOnal Fan BlOWer systeMs
electrical Grounding Instructions: this
appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle.
the black and white wires on the ac box
wiring harness are marked 'Blower', 'light'
and 'aux'. It is important to use the wires
marked 'Blower' or the control will not work
correctly.
BlOtBlDVsc sIGnature cOMManD BlOWer
Blower (300w Max)
The BLOTBLDVSC Blower Kit requires the SCSACM A/C
Module and the TSFSC remote to install and operate this
kit. Refer to blower instructions for installation and remote
instructions for operation.
78D0011
To Junction Box
In Fireplace
{
Light
WHITE
BLACK
WHITE
BLACK
{
BLACK
Optional
WHITE
AUX
Figure 37 -
BLOTBLDVSC Blower Wiring Diagram
FP2684
BLOTSDVSC fan wiring
electrical connections should only be
performed by a qualified licensed electrician.
Main power supply must be turned off before
connecting the fan to the main electrical
power supply or performing service.
GREEN
Connector
Pin To Contro  l  Box
control Box
WDV Series Gas Fireplace
ac Module
FP684
7