Setting Flush/Drain Time
2 2 2 2 2
1)
Press NEXT three times until "START TIME"
flashes on screen. Press ENTER.
2)
Press the UP and DOWN arrows to set the hour.
Press ENTER.
3)
Press the UP and DOWN arrows to set the minute.
Press ENTER.
Note: Select a time that water usage is not expected in the
dwelling. (e.g. 2:00 a.m.)
3 3 3 3 3
Setting the Program
Choosing a program:
NOTE: If surface water is the source and the Surface
Water Option Kit is installed, select either Program 3 or
Program 4 in this application.
W a te r
C l a rity
Low
Turb idity
M ediu m
Turb idity
H igh Turbidit y
V ery H igh
Turb idity
Low Turbidity: Less than 0.5 NTU
Medium Turbidity: Peaks to 1.0 NTU, less than 72 min.
per day.
High Turbidity: Peaks to 5.0 NTU, less than 72 min. per
day.
Very High Turbidity: Peaks to 10.0 NTU, less than 72
min. per day.
C leaning
Sequence
Advanced
P ro gram 1
2 flushes
P lus
P ro gram 2
4 flushes
C ontro ller
2 flushes and
P ro gram 3
2 flushes and
P ro gram 4
FIGURE 3
A d v a n ce d
P l u s
C o n tro ll e r
P rogram 1
P rogram 2
P rogram 3
P rogram 4
A ppro ximate
Water
C onsumptio n
per C leaning
D uratio n
C ycle at 5 gpm
2.5 minutes
7.5 US Gal
6 minutes
1 5 US Gal
1 drain
8.5 minutes
1 3.5 US Gal
2 drains
1 6.5 minutes
1 9.5 US Gal
1)
Press NEXT four times until "PROGRAM"
flashes on screen.
2)
Press ENTER.
3)
Press the UP and DOWN arrows to set the
Program number. Select the appropriate Program
for your application. Press ENTER.
4 4 4 4 4
Setting the Flush/Drain Interval:
1)
Press NEXT five times until "t:01" appears on
screen.
2)
To change the flush/drain interval setting, hold
the UP and DOWN arrows down together and
press NEXT. Release all buttons and repeat to
shift to the next interval. There are five interval
settings to choose from:
No. of
Flush / Dra in
Flush/Dra in
Inte rva l
Cycle s pe r
S e tting
Da y
t:01
once
t:02
2 times
t:04
4 times
t:08
8 times
t:24
24 tim es
Note: Under conditions of turbid water and high usage of
the System, select a Flush/Drain Interval setting
appropriate to the specific application. Increase
frequency of flush/drain cycle if the System TMP rises too
quickly. Increasing the number of Flush/Drain cycles per
day will prolong the life of the System; however, more
water will be used for system cleaning purposes.
FIGURE 4
FIGURE 5
Tim e Inte rva l
Be tw e e n
Flush/Dra in Cycle s
24 hours
12 hours
6 hours
3 hours
1 hour
6