Listing Label - Travis Industries Lopi Answer Owner's Manual

Lopi answer wood stove owner's manual
Hide thumbs Also See for Lopi Answer:
Table of Contents

Advertisement

36

Listing Label

CM
Report No. B0514PRT-001
Control No. 4000515
PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer's installation and operating instructions. Contact your local building or fire officials
about restrictions and installation inspection in your area. Refer to local building codes and manufacturer's instructions for precautions required for passing a
chimney through a combustible wall or ceiling. Do not run a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue
serving another appliance. Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building
or fire officials.
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6" diameter, minimum 24 MSG black, with listed UL-103 HT factory-built chimney, suitable for
use with solid fuels or masonry chimney. Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Pedestal or legs are required.
MANUFACTURED HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. In addition, manufactured
home installations require outside air - use the optional pedestal or outside air boot.
AMERI-TEC model DCC connector with model HS chimney
DURA-VENT model DVL connector with DURA-PLUS chimney
GSW-JAKES EVANS SUPERPIPE 2100
I.C.C. EXCEL (103-HT) chimney with HP connector
FREESTANDING CLEARANCE DIAGRAM
BACKWALL
D
A
A
Factory-Built (Z.C.) Fireplace installations require a minimum 24" starter section directly connected to the fireplace chimney or a full re-line. Factory-Built (Z.C.)
Fireplace chimney must have a minimum cross-sectional area of 28.85 square inches. The Factory-Built (Z.C.) Fireplace damper and control must be removed, or
secured in the open position. For minimum Factory-Built (Z.C.) Fireplace firebox size, see manufacturer's installation instructions. Factory-Built (Z.C.) Fireplace floor
protection must be 3/8" minimum non-combustible material or equivalent, extending 16" in front of insert and 8" to both sides. A metal deflector plate must be installed
if the flue collar is not completely behind the Lintel plate of the Factory-Built (Z.C.) Fireplace openings.
Electrical Rating:
Optional Blower:
Do not route power cord under or in front of appliance.
Replace glass only with 5mm neoceramic or
ceramic glass.
Made in U.S.A.
© Travis Industries
Listing Label
DO NOT REMOVE THIS LABEL
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSTALLATION AND RESTRICTIONS IN YOUR AREA.
SUITABLE FOR USE IN CONVENTIONAL RESIDENTIAL INSTALLATIONS, MANUFACTURED HOMES AND ALCOVES.
CONFORMS TO: UL STD 1482, CERTIFIED TO ULC STD S627-00; ULC STD S628-M93
FREESTANDING INSTALLATION
Minimum Clearances
To Combustibles And
Hearth Requirements:
A. Sidewall to Unit
B. Backwall to Unit
C. Corner to Unit
D. Sidewall to Connector
E. Backwall to Connector
F. Corner to Connector
G. Side & Rear Floor Protection
US: 6 in. (153 mm) / CAN: 8 in. (204 mm)
H. Front Floor Protection
US: 16 in. (407 mm) / CAN: 18 in. (458 mm)
ADJACENT WALL
E
B
F
45˚
STOVE
C
FACTORY-BUILT (Z.C.) FIREPLACE OR MASONRY FIREPLACE INSTALLATION
MANTEL
D
C
B
INSERT
F
E
NON-COMBUSTIBLE
HEARTH
EXTENSION
FIREPLACE FACING
115V., 60 Hz., 1.8 Amps
SKU # 99000128, 99000138
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with July 1990 particulate emission standards.
2011
2012
2013
2014
Jan
Feb
MODEL:
ANSWER
Certified for USA and Canada
METALFAB model DW connector with TG chimney
OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
SELKIRK METALBESTOS model DS connector with model SSII chimney
Singlewall Connector
Alcove, Manufactured Home and Reduced
Conventional Residential
Clearance Conventional Residential
Installations
18 in. / 458 mm
16.5 in. / 420 mm
10 in. / 254 mm
27 in. / 686 mm
19.5 in. / 496 mm
19.5 in. / 496 mm
US: 6 in. (153 mm) / CAN: 8 in. (204 mm)
US: 16 in. (407 mm) / CAN: 18 in. (458 mm)
ALCOVE SPECIFICATIONS
FLOOR PROTECTOR
Max. Alcove Depth:
48 in. (1220 mm)
Min. Alcove Height:
See Owner's Manual
G
Min. Alcove Width:
See Owner's Manual
H
Minimum Clearance to
Combustibles and Hearth
Requirements
A.
B.
C.
With Shield
D.
With Shield
E. (US)
E. (Can)
F.
DATE OF MANUFACTURE
Mar
Apr
May
Jun
Jul
Aug
100-01332
SERIAL NO:
Installations
13 in. / 331 mm
9 in. / 229 mm
7.5 in. / 191 mm
21.5 in. / 547 mm
11.5 in. / 293 mm
16.5 in. / 420 mm
FLOOR PROTECTION DIAGRAM
Floor protection must be a non-combustible
material extending beneath the heater and to
G
the front, sides and back as indicated. See
G
Owner's Manual for examples of non-com-
STOVE
bustible materials that can be used.
FRONT
Do not obstruct space beneath heater.
Factory-Built
Masonry
Fireplace
(Z.C.) Fireplace
Installations
Installations
30.0 in. (762 mm)
13.0 in. (331 mm)
12.0 in. (305 mm)
9.5 in. (242 mm)
12.0 in. (305 mm)
12.0 in. (305 mm)
N/A
N/A
24.0 in. (610 mm)
15.5 in. (394 mm)
N/A
N/A
16.0 in. (407 mm)
16.0 in. (407 mm)
18.0 in. (458 mm)
18.0 in. (458 mm)
8.0 in. (204 mm)
8.0 in. (204 mm)
Manufactured by:
TRAVIS INDUSTRIES, INC.
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
www.travisproducts.com