3. Insert adapter (i.e., needle) into item to be inflated.
4. Turn on the Inflator Power Switch — inflate to desired pressure or fullness.
IMPORTANT NOTE: Small items such as volleyballs, footballs, etc. inflate very rapidly. Do not over-inflate.
5. Remove adapter.
6. Switch the Inflator Power Switch off.
7. Allow unit to cool before storing away.
8. Store inflator hose and tire fitting in storage compartment.
WARNING: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: FOLLOW ALL SAFETY INSTRUCTIONS FOUND IN THE "SPECIFIC
SAFETY INSTRUCTIONS FOR INFLATORS" SECTION OF THIS INSTRUCTION MANUAL.
CARE AND MAINTENANCE
All batteries lose energy from self-discharge over time and more rapidly at higher temperatures. When the unit is not in use, we recommend that
the battery is charged at least every 120 days.
Never submerge the unit in water. If the unit gets dirty, gently clean the outer surfaces of the unit with a soft cloth moistened with a mild solution of
water and detergent.
There are no user-replaceable parts. Periodically inspect the condition of adapters, connectors and wires. Contact manufacturer to replace any
components that have become worn or broken.
Battery replacement/disposal
BATTERY REPLACEMENT
The battery should last the service life of the unit. Contact manufacturer for any information you may need.
SAFE BATTERY DISPOSAL
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed of properly. Recycling is required,
contact your local authority for information. Failure to comply with local, state and federal regulations can result in fines,
or imprisonment.
To locate a free recycling program collection center near you, go to www.call2recycle.org.
WARNINGS:
• Do not dispose of the battery in fire as this may result in an explosion.
• Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire).
• Do not expose battery to fire or intense heat as it may explode.
12 volt DC charger plug fuse replacement
The fuse in the plug end of the 12 volt DC charger protects the adapter' s charging circuit. If the 120 volt AC charger operates, but the DC charging adapter
does not, then this fuse may be opened (blown).
To replace the fuse:
1. Unscrew the end cap of the DC plug (counterclockwise).
2. Remove spring center contact and fuse.
3. Check fuse with a continuity checker.
4. If blown, locate a replacement 8 amp volt fuse.
5. Replace the fuse, spring, contact and end cap.
6. Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.
7. Test for proper operation of the 12 Volt DC Charging Adapter.

TROUBLESHOOTING

Unit Fails to Jump-Start
• Make sure unit' s power switch is in the on position.
• Check that jump-starter has a full charge. Recharge unit if necessary.
• Make sure a proper polarity cable connection has been established.
USB Power Port will not power appliance
• Make sure the USB Charging Port Power Button is in the on position.
• Check that Jump-Starter has a full charge. Recharge unit if necessary.
LED Area Light does not come on
• Make sure the LED Area Light ON/OFF button is in the on position
• Check that Jump-Starter has a full charge. Recharge unit if necessary.
Portable Inflator will not inflate
• Make sure the Inflator Power Switch is in the on position.
• Check that Jump-Starter has a full charge. Recharge unit if necessary.
8
• Make sure connector is pushed to valve stem and thumb latch is closed when attempting to inflate tires; or nozzle (adapter) is securely inserted
into connector (chuck) on all other inflatables.
ACCESSORIES
Recommended accessories for use with your tool are available from your local dealer or authorized service center. If you need assistance regarding
accessories, please contact manufacturer at (877) 571-2391.
WARNING: The use of any accessory not recommended for use with this appliance could be hazardous.
SERVICE INFORMATION
Whether you need technical advice, repair, or genuine factory replacement parts, contact the manufacturer at (877) 571-2391.
ONE-YEAR LIMITED WARRANTY
Manufacturer warrants this product for one year against any defects in material or workmanship. The defective product will be replaced or
repaired at no charge in either of two ways.
The first, which will result in exchanges only, is to return the product to the retailer from whom it was purchased (provided that the store is a
participating retailer). Returns should be made within the time period of the retailer' s policy for exchanges (usually 30 to 90 days after the sale).
Proof of purchase may be required. Please check with the retailer for their specific return policy regarding returns that are beyond the time set for
exchanges. The second option is to return the product (prepaid) to the manufacturer for repair or replacement at our option. Proof of purchase
may be required.
This warranty does not apply to accessories. This warranty gives you specific legal rights and you may have other rights which vary from state to
state or province to province. This product is not intended for commercial use.

SPECIFICATIONS

Boost Ampere:
12Vdc, 450A
instantaneous
Battery Type:
Maintenance-free, sealed lead acid, 12 volt DC, 17aH
Area Light:
1 long-life white LED
USB Port:
5Vdc, 500mA
DC Accessory Outlet:
12Vdc, 5A
Inflator Maximum Pressure:
120 PSI
Imported by
Baccus Global
399 NW 2nd Avenue, Suite 150,
Boca Raton, FL 33432
(877) 571-2391
, 5 seconds 300A
RD052810
9

Hide quick links: