Stanley J45C09 Instruction Manual page 3

450 amp battery jump-starter with compressor
Table of Contents

Advertisement

Available languages

Available languages

• Check for damaged parts. A part that is damaged should be properly repaired or replaced by an authorized service center before further use
unless otherwise indicated elsewhere in this instruction manual. Have defective switches replaced by authorized service center. Do not use tool if
switch does not turn it on and off.
• Do not operate this appliance near flammable liquids or in gaseous or explosive atmospheres. Motors in these tools normally spark,
and the sparks might ignite fumes.
• Never submerge this unit in water; do not expose it to rain, snow or use when wet.
• To reduce risk of electric shock, disconnect the unit from any power source before attempting maintenance or cleaning. Turning off controls
without disconnecting will not reduce this risk.
• This equipment employs parts (switches, relays, etc.) that produce arcs or sparks. Therefore, if used in a garage or enclosed area, the
unit MUST be placed not less than 18 inches above the floor.
• Do not use this unit to operate appliances that need more than 5 amps to operate from the 12 volt DC accessory outlet.
• Do not insert foreign objects into either the USB outlet or the 12 volt DC accessory outlet.
SPECIFIC SAFETY INSTRUCTIONS FOR CHARGING THIS UNIT
• IMPORTANT: This unit is delivered in a partially charged state. Fully charge unit with a household extension cord (not supplied) for a full 24
hours before using for the first time. You cannot overcharge the unit using the AC charging method.
• To recharge this unit, use only the supplied AC Charging Adapter.
• All ON/OFF switches should be in the OFF position when the unit is charging or not in use. Make sure all switches are in the OFF position before
connection to a power source or load.
WARNING: SHOCK HAZARD
• Do not operate charger with damaged cord or plug – replace the cord or plug immediately.
• Do not operate charger if it has received a sharp blow, been dropped, or otherwise damaged in any way; take it to a qualified
serviceman.
• Do not disassemble charger; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of
electric shock or fire.
• Outdoor use extension cords. When appliance is used outdoors, use only extension cords intended for use outdoors and so marked.
• Extension cords. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry
the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. The following
table shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gage. The smaller
the gage number, the heavier the cord.
MINIMUM GAGE FOR CORD SETS
Volts
120V
0-25
(0-7,6m)
240V
0-50
(0-15,2m)
Ampere Rating
0'-25'
More
Not more
Than
Than
0 -
6
18
6 -
10
18
10 -
12
16
12 -
16
14
• When an extension cord is used, make sure that:
a) the pins of extension cord are the same number, size and shape as those in the charger,
b) the extension cord is properly wired and in good electrical condition,
c) the wire size is large enough for the AC rating of the charger.
CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: Pull cord by plug rather than cord when disconnecting the 120V AC
Charging Adapter from the unit.
CAUTION: TO REDUCE THE RISK OF PROPERTY DAMAGE WHEN CHARGING USING THE 12 VOLT DC METHOD:
• Recharge using this method only when necessary. Frequent use the the 12 Volt DC charging method may shorten battery life.
• DO NOT EXCEED 6 HOURS CHARGING TIME USING THIS METHOD.
SPECIFIC SAFETY INSTRUCTIONS FOR COMPRESSORS
CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: Never leave the inflator unattended while in use.
WARNING: BURST HAZARD:
• Carefully follow instructions on articles to be inflated.
• Never exceed recommended pressures. Bursting articles can cause serious injury.
• Always check pressure with the pressure gauge.
Total Length of Cord in Feet
26-50
51-100
101-150
(7,6-15,2m)
(15,2-30,4m)
(30,4-45,7m)
51-100
101-200
201-300
(15,2-30,4m)
(30,4-60,9m)
(60,9-91,4m)
Extension Cord Length
26'-50'
51 '-100 '
101' -150 '
American Wire Gage (AWG)
16
16
14
16
14
12
16
14
12
12
Not Recommended
4
CAUTION: TO REDUCE THE RISK OF PROPERTY DAMAGE:
Do not operate inflator continuously for longer than approximately 10 minutes, depending on ambient temperatures, as it may overheat. In such
event, inflator may automatically shut down. Turn off the Inflator Power Switch immediately and restart after a cooling down period of
approximately 10 minutes.
SPECIFIC SAFETY INSTRUCTIONS FOR JUMP STARTERS
WARNING: BURST HAZARD
Do not use the unit for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to
persons and damage property. Use the unit for charging/boosting a lead-acid battery only. It is not intended to supply power to a low-voltage
electrical system other than in a starter-motor application.
• Use of an attachment not supplied, recommended or sold by manufacturer specifically for use with this unit may result in a risk of electrical
shock and injury to persons.
WARNING: RISK OF EXPLOSIVE GASES
• Working in the vicinity of a lead acid battery is dangerous. Batteries generate explosive gases during normal battery operation. For this reason, it
is of the utmost importance that each time before using the jump-starter you read this manual and follow instructions exactly.
• To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any
equipment you intend to use in the vicinity of the battery. Review cautionary markings on these products and on the engine.
CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:
• NEVER ATTEMPT TO JUMP-START OR CHARGE A FROZEN BATTERY.
• Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-started. Before jump-starting, read the vehicle' s
owner' s manual to confirm that external-starting assistance is suitable.
• When working with lead acid batteries, always make sure immediate assistance is available in case of accident or emergency.
• Always have protective eyewear when using this product: contact with battery acid may cause blindness and/or severe burns. Be aware of first
aid procedures in case of accidental contact with battery acid.
• Have plenty of fresh water and soap nearby in case battery acid contacts skin.
• Never smoke or allow a spark or flame in vicinity of vehicle battery, engine or power station
• Remove personal metal items such as rings, bracelets, necklaces and watches when working with a lead acid battery. A lead acid battery can
produce a short circuit current high enough to weld a ring, or similar metal object, to skin, causing a severe burn.
• Do not wear vinyl clothing when jump-starting a vehicle when jump-starting a vehicle, friction can cause dangerous static-electrical sparks.
• Jump-start procedures should only be performed in a safe, dry, well-ventilated area.
• Always store battery clamps when not in use. Never touch battery clamps together. This can cause dangerous sparks, power arcing and/or
explosion.
• When using this unit close to the vehicle' s battery and engine, stand the unit on a flat, stable surface, and be sure to keep all clamps, cords,
clothing and body parts away from moving vehicle parts.
• Never allow red and black clamps to touch each other or another common metal conductor — this could cause damage to the unit and/or
create a sparking/explosion hazard.
a) For negative-grounded systems, connect the POSITIVE (RED) clamp to the POSITIVE ungrounded battery post and the NEGATIVE (BLACK) clamp
to the vehicle chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines or sheet-metal body parts.
Connect to a heavy gauge metal part of the frame or engine block.
b) For positive-grounded systems, connect the NEGATIVE (BLACK) clamp to the NEGATIVE ungrounded battery post and the POSITIVE (RED) clamp
to the vehicle chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines or sheet-metal body parts.
Connect to a heavy gauge metal part of the frame or engine block.
• If the connections to the battery' s POSITIVE and NEGATIVE terminals are incorrect, the Reverse Polarity Indicator will light (red) and the unit will
sound a beep. Disconnect clamps and reconnect to battery with correct polarity.
• Always disconnect the negative (Black) jumper cable first, followed by the positive (Red) jumper cable, except for positive grounded systems.
• Do not expose battery to fire or intense heat since it may explode. Before disposing of the battery, protect exposed terminals with heavy-duty
electrical tape to prevent shorting (shorting can result in injury or fire).
• Place this unit as far away from the battery as cables permit.
• Never allow battery acid to come in contact with this unit.
• Do not operate this unit in a closed area or restrict ventilation in any way.
• This system is designed to be used only on vehicles with a 12 volt DC battery system. Do not connect to a 6 volt or 24 volt battery system.
• This system is not designed to be used as a replacement for a vehicular battery. Do not attempt to operate a vehicle that does not have a battery
installed.
• Excessive engine cranking can damage a vehicle' s starter motor. If the engine fails to start after the recommended number of attempts,
discontinue jump-start procedures and look for other problems that may need to be corrected.
• Do not use this jump-starter on a watercraft. It is not qualified for marine applications.
• Although this unit contains a non-spillable battery, it is recommended that unit be kept upright during storage, use and recharging. To avoid
possible damage that may shorten the unit' s working life, protect it from direct sunlight, direct heat and/or moisture.
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

J5c09

Table of Contents