Installation Diagram Of Indoor And Outdoor Units - Toshiba RAS-13SKHP-E Service Manual

Split wall type air conditioner
Table of Contents

Advertisement

8-2. Installation Diagram of Indoor and Outdoor Units

5
Super Oxi Deo filter
Super Sterilizer filter
3
Batteries
2
Wireles s remote c ontrol
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (− ) positions.
6
8
4
R emote c ontrol holder
Pan head
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
Before installing the wireless remote controller
2 Wireless remote controller
Hook
1
Installation
plate
Shield pipe
Saddle
Extension
drain hose
(Not available,
provided by installer)
– 29 –
FILE NO. SVM-07033
For the rear left and left piping
Wall
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
operation.
Do not allow the drain hose to
get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain
hose sloped downward.
The auxiliary piping can be
connected to the left, rear left,
rear right, right, bottom right
or bottom left.
Right
Rear right
Left
Rear
Bottom
left
right
Bottom left
Insulate the refrigerant pipes
separately with insulation, not
together.
6 mm thick heat resisting
polyethylene foam