How To Set Remote Control Selector Switch - Toshiba RAS-13SKHP-E Service Manual

Split wall type air conditioner
Table of Contents

Advertisement

8-5-4. Wiring connection
1. Remove the valve cover from the outdoor unit.
2. Connect the connecting cable to the terminal as
identified with their respective matched numbers on
the terminal block of indoor and outdoor unit.
3. When connecting the connecting cable to the
outdoor unit terminal, make a loop as shown in the
installation diagram of indoor and outdoor unit, to
prevent water coming in the outdoor unit.
4. Insulate the unused cords (conductors) from any
water coming in the outdoor unit. Proceed them so
that they do not touch any electrical or metal parts.
<Stripping length of connecting cable>
Terminal block
100 mm
10 mm
Earth line
10 mm
50 mm
Connecting
cable
Fig. 8-5-9
CAUTION
• Wrong wiring connection may cause some
electrical parts burn out.
• Be sure to comply with local codes on running
the wire from indoor unit to outdoor unit (size of
wire and wiring method etc.)
• Every wire must be connected firmly.
NOTE
• Wire type: H07RN-F or 245 IEC66 (2.0 mm
more)
Terminal
Earth
Screw
4
1(L) 2(N) 3
line
screw
Cord clamp
2
or
8-6. How to Set Remote Control Selector
Switch
When two Indoor units are Ins talled in the s eparated
rooms , it is not neces s ary to change the s elector
s witches .
Remote control A or B selection
.
When two indoor units are installed in the same room
or adjacent two rooms, if operating a unit , two units
may receive the remote control signal simultaneously
and operate. In this case, the operationcan be preserved
by setting either one indoor unit or remote
control to B setting. (Both are set to A setting in
.
factory shipment.)
The remote control signal is not received when the
.
setting of indoor unit and remote control are different.
There is no relation between A setting/B setting and A
room/B room when connecting the piping and cables.
Remote control A-B selector
To separate using of remote control for each indoor unit
in case of 2 air conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air
conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHK] button on the Remote Control by the
tip of the pencil. "00" will be shown on the
display.
4. Press [MODE] during pushing [CHK]. "B" will shown on the
display and "00" will disappear and
conditioner will turn OFF. The Remote Control B is
memorized.
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
TOSHIBA
"B" Display
"00" Display
Fig. 8-6-1
- 41 -
FILE NO. SVM-07033

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-13s2ah-e

Table of Contents