Toshiba RAS-13SKHP-E Service Manual page 35

Split wall type air conditioner
Table of Contents

Advertisement

Wiring Connection
How to connect the power cord
For the air conditioner that does not have power cord,
connect a power cord to it as mentioned below
(1) Open the air inlet grille upward.
(2) Remove the two screws securing the front panel.
(3) Slightly open the lower part of the front panel, then
pull theupper part of the front panel toward you to
remove it from the rear plate.
(4) After removing the front panel, remove the
power cord connect cover and the cord clamp.
(5) Connect and secure the power supply cord and
secure the cord clamp and the power cord
connect cover.
(6) Put the power supply cord through the notch.
(7) Be sure to smooth the notch with a
Air inlet grille
2
Earth line
Terminal
block
Power supply cord
Fig. 8-4-5
Front panel
1
3
Cord clamp
Screw
Screw
Screw
Power cord
connect cover
− 34 −
FILE NO. SVM-07033
Stripping length of the power supply cord
40 mm
10 mm
N
L
10 mm
30 mm
Fig. 8-4-6
NOTE
Use stranded wire only.
Wire type : H07RN-F or more
CAUTION
For the air conditioner with the power supply cord
If the power supply cord is damaged, it must be
replaced by the manufacturer, the service
agency, or another similarty qualitied
person in order to avoid hazard.
Taking out the power cord
Put the power supply cord
through the notch.
Earth line
Notch

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-13s2ah-e

Table of Contents