Toshiba RAV-SM564UT-E Service Manual page 69

Air-conditioner split type
Hide thumbs Also See for RAV-SM564UT-E:
Table of Contents

Advertisement

Toshiba SDI / DI tuotteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy.
No.
Item
12
Louver control
<<Selection of Swing mode>>
(Continued):
• For the Swing mode, the following three types of modes are
In case of 4-way
Discharge
Cassette type
• Three types of the swing modes can be also selected and set
• In case of selecting the Swing mode, "Dual swing" or "Cycle
<<Louver lock (Louver fix)>>
• For the air direction setup for each discharge port, the louver
• An arbitrary air direction of an arbitrary louver can be
• The louver lock can be set by registering the setup data to
Outline of specifications
selectable and settable by keeping Swing/Direction
button pushed for 4 seconds or more on the remote controller.
Q
Standard (4 pieces: same phase) swing
→ Data: [0001 (At shipment)]
When Swing operation is selected, four louvers align at the
horizontal discharge position and then start the Swing
operation at the same time.
R
→ Data: [0002]
Dual swing
When operation is selected, the louvers of louver No. [01]
and [03] move to the horizontal discharge position, the
louvers of louver No. [02] and [04] move to the downward
discharge position and then start the Swing operation at
the same time.
S
Cycle swing → Data: [0003]
When operation is selected, the louver No. [01] moves to
the horizontal discharge position, [03] to the downward
discharge position, [02] and [04] to the middle position and
then start the Swing operation at the same time.
by the setup data of Item code (DN) [F0].
swing", the following numerals is displayed at the center of
the remote controller screen for approx. 3 seconds when
SWING/FIX
button was pushed to select [SWING].
(No display for the standard swing)
Alternate lighting
(0.5 sec.)
Dual swing
position can be locked during the normal operation.
registered and set by keeping
4 seconds or more on the remote controller.
Item code (DN) [F1] to [F4] according to the following table.
Item code
Objective louver No.
F1
01
F2
02
F3
03
F4
04
www.ilmalämpöpumput.com
SWING/FIX
Alternate lighting
(0.5 sec.)
Cycle swing
UNIT
LOUVER
button pushed for
Setup data
0000: Release (At shipment)
0001: Horizontal discharge position
~
0005: Downward discharge position
– 69 –
Remarks
On the remote control-
ler before the wired
remote controller
(RBC-AMT31E), the
mode cannot be moved
to the select mode
SWING/FIX
even if pushing
button for a long time.
Carry out setting
operation during stop of
the unit; otherwise the
unit stops operation.
The standard swing
performs the same
swing operation as the
present operation
(2 series).
For the setting opera-
tion, refer to [How to
set up type of the
swings] in Item "Setup
at local site/Others".
On the remote controller
before the wired remote
controller
(RBC-AMT31E),
flashing showing the
Swing mode is not
indicated.
On the remote control-
ler before the wired
remote controller
(RBC-AMT31E),
UNIT
LOUVER
button is not
provided.
Carry out setting
operation during stop of
the unit; otherwise the
unit stops operation.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents