Toshiba RAV-SM564UT-E Service Manual page 208

Air-conditioner split type
Hide thumbs Also See for RAV-SM564UT-E:
Table of Contents

Advertisement

Toshiba SDI / DI tuotteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy.
No.
Part name
Rear cabinet
1) Perform works of items 1 of 1 and 2 , 3 .
5
2) Take off fixed screws for the bottom plate.
(ST1T Ø4 × 10L, 3 pcs.)
3) Take off fixed screws for the heat exchanger.
(ST1T Ø4 × 10L, 2 pcs.)
4) Take off fixed screw for the valve mounting
plate. (ST1T Ø4 × 10L, 1 pc.)
Fan motor
1) Perform works of items 1 of
6
2) Take off the flange nut fixing the fan motor and
the propeller.
• Turning it clockwise, the flange nut can be
3) Remove the propeller fan.
4) Disconnect the connector for fan motor from
the inverter.
5) Take off the fixing screws (3 pcs.) holding by
hands so that the fan motor does not fall.
NOTE:
Tighten the flange nut with torque 4.9Nm
(50kgf/cm).
Procedure
loosened. (To tighten the flange nut, turn
counterclockwise.)
www.ilmalämpöpumput.com
1
and
2
.
Flange nut
Fan
motor
– 208 –
Remarks
Rear cabinet
Loosen the nut by
turning clockwise
Propeller fan