Set the brake ................5 Install Crank handle for high pressure hose reel/cord reel ...6 Fill up detergent tanks ............6 Fill up tank for Gerni AntiStone (Anti-Scale) ......6 Antiscale ................6 Fill up fuel tank ..............7 Connecting the high pressure hose ........7 Connecting the water supply ..........8...
Secure it with tie-downs supplied or recommended sure cleaner be connected via a and apply the parking brake on by Gerni. The use of other residual current circuit breaker. the castor wheel. cleaning chemicals may This device stops the supply of...
Page 5
NEPTUNE 5 FA major components. Store the cleaner where Cord length Cross section it will not be exposed to up to16 A up to 25 A CAUTION! frost or use antifreeze High-pressure water jets can liquid! up to 20 m ø1.5mm²...
fi re. Ensure that the machine is regu- and the leakage current must larly serviced by authorized Gerni be measured. Furthermore, a Electrical equipment dealers in accordance with the visual inspection of the mains maintenace plan.
7 Receptacle for service 23 Water supply connection crane and lifting ring 24 Tank fi ller for anti-freeze 8 Top cover release 25 Tank fi ller for Gerni Anti- 9 Service door release Scale 10 Crank handle for 26 Canister for detergent B...
1. Fill up detergent tanks (A) and (B) with prediluted detergent. Capacity see chapter 9.4 Technical Data Fill up tank for Gerni 1. Fill up Gerni Anti-Stone (Anti- AntiStone (Anti-Scale) Scale)/water softener reser- voir with the sample bottle provided. Gerni AntiStone...
NEPTUNE 5 FA Fill up fuel tank With the machine cold, turned off and disconnected from power supply: 1. Fill fuel tank from a clean con- tainer with a fresh fuel (fuel oil EL, or Diesel oil DIN 51 603), or fuel type recommended by your distributor.
NEPTUNE 5 FA 1. Attach quick connect adapter Connecting the water found with Owners Manual to supply the water supply hose. 2. Rinse the water supply hose briefl y in order to prevent sand an other dirt particles entering into the machine.
NEPTUNE 5 FA Switching on the 1. Turn the main switch to posi- cleaner tion (cold water). 4.2.1 Cold water operation / Hot water operation (up Control electronics accomplishes to 100°C) a self check. The Display shows for approx. 1 NOTE! second „---“.
NEPTUNE 5 FA Using cleaning agents 1. Select desired detergent (A) or (B) and amount by turning the knob to desired percent- age. 2. S p ray t h e o b j e c t t o b e cleaned.
NEPTUNE 5 FA 5 Applications and methods Techniques Effi cient high pressure cleaning is achieved by following a few guide- lines, combined with your own personal experience of specifi c clean- ing tasks. Accessories and detergents, when correctly chosen, can increase the effi...
NEPTUNE 5 FA Some typical cleaning tasks 5.2.1 Agriculture Task Accessories Method Stables Chemical Foam Injec- 1. Soaking – apply foam to all surfaces (bottom to top) Pig Pens, Sties tors and wait for approx. 30 minutes. Foam lance 2. Remove the dirt from surfaces with the high pressure...
Page 15
These are merely several examples of cleaning tasks that can be solved by a pressure washer in asso- ciation with accessories and detergents. Each cleaning task is different. Please consult your local dealer or Gerni representative in order to discuss the best solution for your own cleaning tasks. Options / model variants...
NEPTUNE 5 FA 6 After using the cleaner Switching off the 1. Turn the main switch to posi- cleaner tion „OFF“. 2. Tur n off water supply at faucet. 3. Squeeze the spray gun trigger until the pressure has bled off.
NEPTUNE 5 FA 7 Maintenance Maintenance Schedule Every six After the fi rst 50 months or Weekly operating hours 500 operating required hours 7.2.1 Water fi lters 7.2.2 Oil fi lter 7.2.3 Checking the pump oil quality ...
Page 18
NEPTUNE 5 FA 7.2.3 Checking the pump oil 1. Check color of pump oil. If the oil has a grey or white quality shade, change the oil (see chapter 7.2.4) 2. Top off oil level with fresh oil if necessary.
NEPTUNE 5 FA 8 Troubleshooting Indications on Display Indication Cause Remedy on Display Contact Gerni Service > Flow sensor fault Cold water operation possible > Water supply turned off or inadequate supply • Required volume fl ow and pressure see to machine chapter 9.4 Technical Data...
> Low fuel level • Fill fuel tank Cold water operation possible > Low Gerni AntiStone (Anti- • Fill Gerni AntiStone (Anti-Scale) tank Scale) level > Service interval: Service due Contact Gerni Service fl ashing in 20 hours > Service interval expired Contact Gerni Service >...
The guarantee is invalidated if the cessories. machine is not operated in ac- The burner coil on all Gerni Clean- cordance with these instructions ing Systems, Inc. hot water/steam or otherwise abused. The guaran- cleaners is under warranty for five...
NEPTUNE 5 FA EU Declaration of EU Declaration of Conformity Conformity Product: High Pressure Cleaner Type: NEPTUNE 5 Description: 400 V 3~ 50 Hz IPX5 400/230 V 3~ 50Hz IPX5 230-240 V 1~ 50Hz IPX5 The design of the unit corresponds to the...
NEPTUNE 5 FA Technical Data NEPTUNE 5 5-61 FAX Voltage 400 V / 3~ / 50Hz Fuse Power rating Power consumption 15.4 Type of protection IP X5 Working pressure 210(21) (Mpa) Permissible pressure (Mpa) Volume fl ow (max) 1080 Volume fl ow Q...
Page 24
Nilfi sk Advance Pty Ltd 48 Egerton Street Silverwater NSW 2128 Ph: 1300 556 710 Email: customerservice@nilfi sk-advance.com.au...