King Canada KCG-2000i Instruction Manual page 5

2000w gasoline digital inverter generator
Table of Contents

Advertisement

1. Fuel cap. Make sure the fuel cap is always screwed on tightly. Use
unleaded gasoline only! 7 Liter capacity.
2. Spark plug access cover. Periodically the spark plug must be
checked and maintained, see maintenance section.
3. 20 Amp AC Breaker. The AC breaker turns off automatically when
the load exceeds the generator rated output. Reduce the load to
within specified generator rated output if AC breaker turns off.
4. Overload indicator light. Lights up when generator is overloaded.
5. Power indicator light. Lights up when generator is ready to use.
6. Low oil warning indicator light. Lights up when oil level is too
low. This generator detects and shuts off automatically when the oil
level is too low. In case of an auto shut-off and the indicator light is
ON, check oil level with dipstick (#19) and fill to recommended level
with SAE 10W30 engine oil.
7. Economical mode switch. Adjusts the engine speed based on
connected load, for improved fuel consumption.
8. Engine switch. Must be placed to the "On" position before pulling
the recoil starter handle.
9. Recoil starter. Starts the engine.
10. DC Outlet. Use to power 12V DC items.
MODEL
Peak Wattage (starting)
Running Wattage
AC Outputs
DC Output
Engine (OHV)
No load speed
Displacement (cc)
Fuel
Fuel tank (L)
Oil capacity (L)
Run time
Noise level
Dimensions (LxWxH)
Weight
GETTING TO KNOW YOUR
DIGITAL INVERTER GENERATOR
11. 10 Amp DC Reset Button. Resets the 12V DC outlet.
12. Grounding terminal. This generator must be grounded, see
grounding instructions.
13. Duplex AC 120V outlets. Plug up to 2-120V appliances or a power
bar, make sure the amps requirement does not exceed max amps
(17 amps) or else the AC breaker will automatically shut-off the
power output.
14. Carburetor throttle lever (choke). Once the engine is started, it is
necessary to gradually turn the carburetor throttle lever to the "Off"
position, see instructions futher in this manual.
15. Fuel Shut-off Valve. Regulates the flow of fuel to the engine. The
fuel shut-off valve must be fully opened before starting the engine.
16. Fuel Pump Primer. To start, press fuel pump engine primer 3-5
times. For initial season start or dry starts, prime engine 30-50
times.
17. Caburetor.
18. Air cleaner filter/cover. Periodically the air cleaner filter must be
checked and maintained, see maintenance section.
19. Oil gauge dipstick. Check the oil level using this oil gauge
dipstick.
KCG-2000i
2100W
2000W
1(2x 120V/16.7A)
12V (8.3A)
4.5 HP
5,400 RPM
125
Unleaded Gasoline
7
0.45
5-6 hours
57 dB(A)
21-1/2" x 11-1/2" x 20"
58 lbs