Town & Country Fireplaces TC42 Instructions Manual

Tc42 country home burner kit

Advertisement

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
These instructions are supplementary to the Installation and
Operating Instructions supplied with the fi replace and should be
kept together. Refer to the Installation and Operating Instructions
for proper gas supply, safety requirements and operating
instructions
270409-12
TC42
COUNTRY HOME
BURNER KIT
INSTRUCTIONS
PART#
TC42.NG02.C
FOR TC42
TC42.NG02.C
5056.426.C2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TC42 and is the answer not in the manual?

Questions and answers

Summary of Contents for Town & Country Fireplaces TC42

  • Page 1 Operating Instructions supplied with the fi replace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions TC42 COUNTRY HOME BURNER KIT INSTRUCTIONS PART# TC42.NG02.C FOR TC42 270409-12 TC42.NG02.C 5056.426.C2...
  • Page 2: Contents Of Package

    Contents of Package • BURNER ASSEMBLY (including pilot and manifold) • LOG GRATE • TC42 LOGS • EMBER MATERIAL • HARDWARE PACKAGE • AIR DEFLECTOR TC42.NG02.C 270409-12...
  • Page 3 (Fig. # 4) 5. Attach rear defl ector to rear of grate using the two screws provided. (Fig. # 5) TC42.NG02.C 270409-12...
  • Page 4: Ember Material Placement

    Note: Ember material placement and amount will affect fl ame appearance. More ember material results in lower fl ame height. Add or remove as needed until desired fl ame affect is achieved. Fig. # 5 AIR DEFLECTOR SECURING SCREWS GLOWING EMBERS TC42.NG02.C 270409-12...
  • Page 5: Log Placement

    Fig. # 7 Fig. #8 Fig. #9 Fig. #12 Fig. #10 Fig. #11 Note: Improper placement of logs will cause sooting on internal parts and glass. The logs may need to be repositioned slightly to avoid excessive fl ame impingement. TC42.NG02.C 270409-12...
  • Page 6: Propane Conversion

    With a ½” wrench remove the natural gas orifi ce (#25) and replace with propane orifi ce (3/32”)(our part # 5021.31) (Fig. #16) Fully open the primary air shutter. Reinstall the manifold and air defl ector. TC42.NG02.C 270409-12...
  • Page 7 (Fig. #20) Minimum rate screw Minimum rate screw Replace the minimum rate screw with the one provided in the propane conversion kit supplied with this fi replace. Ensure that the screw is fully installed. (Fig. #21) TC42.NG02.C 270409-12...
  • Page 8 15. Attach the access panel to the side of the fi rebox with the previously removed gasket must be reinstalled screws. (Fig. #24) after conversion/ installation or servicing has been completed. Failure to do so will overheat and cause premature failure of the control system. TC42.NG02.C 270409-12...
  • Page 9: Gas Pressure Check

    Correct gas pressure requirement: Supply Pressure Natural Gas Propane (For purpose of input adjustment) Minimum 5.0" WC 12.5" WC Maximum 13.9" WC 13.9" WC Manifold Pressure Maximum 3.8" WC 11" WC Minimum 2.1" WC 5.5" WC TC42.NG02.C 270409-12...
  • Page 10: Burner Flame Adjustment

    Operating Instructions manual. 2. Remove the log set and set aside. 3. Loosen the screw in the Primary Air Shutter. 4. Rotate the shutter to increase or decrease the amount of primary air. PRIMARY AIR SHUTTER 5. Reassemble as needed TC42.NG02.C 270409-12...
  • Page 11: Kit Contents

    #5..MAIN SUPPLY TUBE ......5019.223 #2..7 PCS LOG SET ......... 5098.311 #6..PILOT TUBE ........5019.225 #3..ORIFICE, NATURAL GAS (#25) ..5022.12 #7..PROPANE CONVERSION KIT ... TC42.LPCE01 NOT SHOWN KIT CONTENTS: LOG #1 #1..BURNER ASSEMBLY #3..
  • Page 12 TECHNICAL SUPPORT: 1-888-715-2664 www.townandcountryfi replaces.net 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada...

This manual is also suitable for:

Tc42.ng02.c

Table of Contents

Save PDF