InoTec SCAMAX 2600 Service Manual page 27

Document scanner
Table of Contents

Advertisement

The controller board manages all functions of the SCAMAX 2600/4000.
The scanner communicates with the scan PC via a serial interface (RS232), which controls the cameras,
motors, Dtplus boards and the endorser, according to commands received.
In addition, with the SCAMAX2600, image data from the cameras are processed for video interface (8 Bit
parallel). Binarisation, when using fixed threshold or one-dimensional automatic threshold, is executed in
the LCA's of the controller as well.
DIL-Switches are used to set the baud rate and select the appropriate scanner type. As can be seen from
the diagram switch 1 is used to set the baud rate. It should always be set to 19200. Switches 2 to 4 are to
be set according to the table below.
9600
Baud
1
19200
Baud
9600 Baud
19200 Baud
SCAMAX 5000
SCAMAX 2500
SCAMAX 4000
SCAMAX 2600
®
SCAMAX
2600/4000
2
3
ON
DIL Switch
1
2
Off
On
Off
On
Off
On
Tech. Manual 06/2002
4
3
4
Off
Off
Off
Off
On
Off
On
Off