General Purpose Outlet

If desired, a duplex receptacle with weatherproof cover (supplied by installer) may be installed in the knockouts on
the lower right side of the Pro Logic enclosure. Per code, the receptacle should be a GFCI type. Alternatively,
connect a standard receptacle to a GFCB.

Pro Logic Control Power

The Pro Logic requires 120VAC, 2A power to operate the control logic circuits and the chlorinator. This power
should be connected to one of the circuit breakers.
!
WARNING: 120VAC only (permanent damage if connected to 240V)
Factory
Prewired
120, 2VA
L1
Neutral
Field
Wired
High Voltage (120/240V) Pool Equipment
All Pro Logic relays are double pole (they make/break both "legs" of 240V circuits) and are rated at 3HP/30A at
240V (1½HP/30A at 120V). Refer to the diagram below for typical relay wiring.
240 VAC
120 VAC
120 VAC
Load
Load
Load
Wiring relays for 240 VAC
Wiring relays for 120 VAC
Wiring GFCB for 120 VAC
Pool Equipment
Pool Equipment
Pool Equipment