Note: In the following step, the motor moisture
shield is attached to the motor bracket with a
Phillips-head screw and 2 tabs that engage a slots
in the motor bracket.
5. Remove the Phillips-head screw, then disengage
the motor moisture shield from the motor
bracket.
Motor Moisture Shield
6. Invert the motor moisture shield, then compress
and remove the wire tie from the shield.
7. Disconnect wires attached to the outlet control
thermistor.
Outlet Control Thermistor
8. Remove the idler pulley assembly from the
motor bracket. (See
Idler Pulley
9. Disconnect the motor wire harness.
10. Disconnect the wires attached to the belt switch.
11. Remove the 1/4-in. hex-head screw that
12. Remove the single vertical and single horizontal
Motor Support
13. Remove the 2 Phillips-head screws that hold
Wire Tie
.)
14. Raise the rear of the motor bracket to clear the
– 29 –
attaches the ground wire to the motor support.
Phillips-head screws that attach the motor
bracket and motor support to the chassis.
Motor Bracket
the top of the motor base plate to the blower
housing.
tab protruding from the bottom of the chassis.
Slide the motor bracket back until the bracket
tabs clear the slots in the chassis. Remove the
motor and blower wheel assembly from the
chassis.
Disconnect
Belt Switch
(Continued Next Page)