5 Troubleshooting

5.1 Before you send in the appliance
Before contacting your authorised Royal dealer, Royal service partner or appliance market, first follow the procedure in the following table to check if you
can handle the problem yourself
WARNING:
Danger of injury! Never use a defective appliance! Always switch off the appliance and disconnect it from the mains before starting troubleshooting
chapter 3.1, „Switching off".
Problem
The appliance will
The power cord is not plugged in.
not start
The socket does not carry current.
Power cord is damaged.
The vacuum
The overheating protection has tripped (possibly
cleaner stops
due to blocked suction channels, extremely dirty
suddenly.
filters, or similar).
Cleaning indicator
The dust container is full.
(Fig. 1/14) lights
up.
The results are
The bypass vent (Fig. 1/8) is open.
unsatisfactory in
spite of the
The nozzle you are using does not suit the
appliance working
flooring.
correctly.
The "carpet/hard floor" selector (Fig. 1/19) is in
the wrong position for the particular type of floor.
The power setting does not suit the flooring.
The dust container is full.
The filter is dirty.
Nozzle, telescopic tube or suction hose are
blocked.
5.2 Accessories/Spare Parts
5.3 Disposal
5.4 Conditions of warranty
5.5 In case of a warranty
claim
5
Troubleshooting
Possible cause
Item number
2700001
3-piece filter set (1 foam plastic motor protection filter +
1 laminar motor protection filter + 1 exhaust filter)
2700002
1 cyclone
M203-4
1 parquet brush
M208-8
1 turbo brush
Ordering address:
page 77, „International Service".
The filters used are made from environment-friendly materials. You may dispose of them in your household
waste.
When the appliance has reached the end of its usefulness, especially if dysfunctions recur, disable the
appliance by pulling the mains plug out of the socket and cutting off the power cord. Dispose of the appliance
in compliance with the environmental protection laws of your country. Electrical waste may not be disposed of
together with domestic waste. Consult your local authorities or your dealer for advice on recycling.
We grant a warranty of 24 months from the date of purchase for the appliance distributed by us. Within
this period we will either repair or replace the appliance or accessory (damages to accessories do not
automatically cause a replacement of the complete appliance) all defects due to manufacturing or materials at
no cost. Damages due to inappropriate use (operation on wrong voltage or type of current, connecting to
unsuitable power supplies, breakage, etc.) are exempt from warranty, as are normal wear and minor defects
that only negligibly influence the appliance's serviceability. Intrusions by unauthorised parties and the use of
spare parts not supplied by Royal Appliance invalidate the warranty. Consumable parts are not included in the
warranty and must be paid for! The warranty is only valid if the date of purchase has been acknowledged by
the dealer's stamp and signature on the warranty card or if a copy of the invoice or sales slip is included with
the sent-in appliance. Warranty work does not extend the warranty period nor does it constitute a claim for a
new warranty!
Send us the appliance with its dust container empty and a short description of the defect in printed letters. Head
your accompanying letter with the notice "warranty claim". Send it including the warranty card or a copy of the
purchase slip to the address
Insert the plug into a mains socket and switch on the appliance
„Vacuum cleaning".
Test the vacuum cleaner at another socket which you are sure carries current.
Have the power cord replaced by Royal Appliance Customer Service, address,
page 77, „International Service".
Switch the appliance off and pull the plug out of the socket.
Eliminate the cause of overheating (e.g. disassembling telescopic tube and suction
hose and removing the obstacle and/or cleaning filters). Wait for about 45 minutes.
After the appliance has cooled off, you may switch it on again.
Empty / clean the dust container
container".
Close the bypass vent (Fig. 1/8).
Change the nozzle,
chapter 2.2, „Vacuum cleaning", step 1.
Set the "carpet/hard floor" selector (Fig. 1/19) to the correct position for the type of
floor,
chapter 2.2, „Vacuum cleaning", step 2.
Set the power to the setting suggested for the flooring,
cleaning", step 6.
Empty / clean the dust container
container".
Clean the respective filter,
chapter 4.2, „Checking and cleaning the cyclone",
chapter 4.3, „Cleaning / changing the laminar motor protection filter" or
4.4, „Cleaning / changing the exhaust filter".
Remove the obstacle. If necessary, use a long wooden stick (e.g. a broomstick) to
do this.
Description
page 77, „International Service".
Solution
chapter 2.2,
chapter 3.4, „Emptying and cleaning the dust
chapter 2.2, „Vacuum
chapter 3.4, „Emptying and cleaning the dust
chapter
15

Advertisement

Table of Contents
loading

Table of Contents