American Fibertek MTX-8410C-SL Instruction Manual

Four channel video multiplexer with bi-directional sensornet data

Advertisement

Quick Links

Instruction Manual
MTX-8410C-SL
MRX-8410C-SL
Four Channel Video Multiplexer
with Bi-directional Sensornet Data
© Copyright 2005, American Fibertek, Inc. 1213JD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTX-8410C-SL and is the answer not in the manual?

Questions and answers

Summary of Contents for American Fibertek MTX-8410C-SL

  • Page 1 Instruction Manual MTX-8410C-SL MRX-8410C-SL Four Channel Video Multiplexer with Bi-directional Sensornet Data © Copyright 2005, American Fibertek, Inc. 1213JD...
  • Page 2 Functional Description ................ 3 Installation ..................3 Power Source ..................4 Power Connection ................4 Input / Output Connections..............4 Data Configuration ................5 MTX-8410C-SL Status LED Indicators..........6 MRX-8410C-SL Status LED Indicators ..........7 Warranty..................... 8 Service Information ................8...
  • Page 3 THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES. To install the MTX-8410C-SL or MRX-8410C-SL it is first necessary to mount the rack flanges to the unit. For rack mounting the ears are installed on the...
  • Page 4 For mounting the unit flush to a wall or other rigid surface, the ears may be installed on the sides with the oval holes flush with the bottom of the unit as in Figure 2. Mount the ears with the #10 flathead screws provided.
  • Page 5 DATA CONFIGURATION There is a rear panel data configuration switch bank preset at the factory for Sensornet data transmission. With the exception of switch # 5, these switches must remain in the positions shown below to properly transmit Sensornet data. Switch # 5 is used to apply a 120Ω...
  • Page 6 /output terminals of the MTX-8410C-SL. An active DATA 2 LED indicates the MTX-8410C-SL has seized the data carrier to allow data flow. The intensity of the indicators will vary with input / output data patterns, however, the Tx and Rx Carrier Detect LEDs will typically appear dimmer than the Sensornet Tx and Rx LEDs.
  • Page 7 MRX-8410C-SL STATUS INDICATORS The MRX-8410C-SL receiver provides the following front panel LED status indicators to aid in installation and troubleshooting: DATA These indicators turn green when any data activity is present. An active DATA 1 LED indicates data is present at the input /output terminals of the MRX-8410C-SL. An active DATA 2 LED indicates the MRX-8410C-SL has seized the data carrier to allow data flow.
  • Page 8 LIFETIME WARRANTY INFORMATION American Fibertek, Inc warrants that at the time of delivery the products delivered will be free of defects in materials and workmanship. Defective products will be repaired or replaced at the exclusive option of American Fibertek. A Return Material Authorization (RMA) number is required to send the products back in case of return.