Brake Test

The brake resistor is
permanently molded
into the underside of
the inverter cover.
• Tub should stop spinning 7 seconds after lid is lifted.
• If the tub takes approximately 10 seconds to stop, check drive belt for wear.
• If tub coasts to stop, brake resistor has failed and inverter/motor assembly must be replaced.
• If the tub takes longer than 25 seconds to stop, the inverter will initiate a long brake time error code.
(See Inverter/Motor Error Codes.)