ELECTRICAL ADJUSTMENT PROCEDURE IDLE CURRENT A. Setting Set the master volume minimum. B. Connection R146 R149 VOLT METER R246 R249 SVR101 SVR201 AMP B D C. Adjustment – Adjust SVR101, SVR201 so that the current through the R146, R149, R246, R249 become 10 milliampere.
SPECIFICATIONS ELECTRICAL PARTS LIST C-800 C-1200 Ref No. Part No. Description Value Ref No. Part No. Description Value R140 R143 3079101275 RES ERD-2FCVG 101T 1/4W R FR 100 Power Output Level AMP B’D (4005185301) R169 R172 f=1kHz, THD+N≤5% (Typical) Q107 Q207 2008005999...
EXPLODED VIEW OF CABINET & CHASSIS/MECHANICAL PARTS LIST C-800/1200 EXPLODED VIEW DWG PARTS, LIST PARTS NAME PARTS NO Q'TY REMARK 048602966611 C-800 FRONT PANEL 048602966612 C-1200 HANDLE 3 SIZE 048603995230 SPONGE FAN 6733996110 SW POWER 4625996611 6503986830 HANDLE BKT 046121676111...