PIPEWORK POSITIONS &
FLUE OPENING
185
D
C
A
A
E
B
B
FRONT VIEW
G
G
3
190
148
155
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR CAMRAY KITCHEN 12/18-18/25-25/32
RS - 155
148
CF - 170
D
C
A
E
B
SIDE VIEW
H
4
RS - 155
CF - 170
148
1
H
2
755**
PIPEWORK POSITIONS &
FLUE OPENING
CAUTION: Ensure there are no pipes,
electric cables, damp proof courses or
other hazards before drilling.
SAFETY:
All relevant safety precautions must be undertaken.
Protective clothing, footwear, gloves and safety
goggles must be worn as appropriate.
PIPEWORK POSITIONS:
A to E (opposite) show the flue and pipe positions:
A - Flow/open vent 1" BSP 12/18, 18/25.
1
1
/
" BSP 25/32.
4
B - Primary drain/cold feed
3
/
" Ø BSP.
4
C - Return 22mm Ø copper 12/18, 18/25.
28mm Ø copper on 25/32 model.
D - Flue outlet 80/125mm Ø.
E - Condensate outlet 21.5mm Ø.
NOTE: For servicing purposes, keep
condensate and pressure relief discharge
pipes away from components and pipework
connections.
IMPORTANT: The flue and pipework
openings are covered with tabbed blanks.
Remove carefully as necessary.
FLUE OPENING:
Follow the diagram opposite to mark the
centre of the flue (1, & 2) for rear opening,
(2 & 3) for side opening or
(1 & 4) for top opening.
** IMPORTANT: for horizontal flues, increase
this height by 52mm for every 1000mm of
horizontal length that the flue opening is
away from the boiler.
NOTE: all horizontal flue sections must rise away
from the boiler by 52mm per metre to ensure that
condensate flows back into the boiler for safe
discharge via the condensate waste pipe.
Make an opening (F, G or H) through the wall
using a core drill or similar at a size relative to
the wall thickness as shown below:
125mm Ø flue:
Wall thickness
Flue hole size
150 - 240mm
155mm Ø
240 - 330mm
160mm Ø
330 - 420mm
165mm Ø
420 - 500mm
170mm Ø
150mm Ø flue:
Wall thickness
Flue hole size
150 - 240mm
180mm Ø
240 - 330mm
185mm Ø
330 - 420mm
190mm Ø
420 - 500mm
195mm Ø
Clear away any debris.