Not Fully Lined Chimney - Stanley Cara Installation And Operating Instructions Manual

Non boiler insert stove
Table of Contents

Advertisement

Fig.4
405mm - 455mm
Step 2
Ensure the floor area is level with the hearth, this
area needs to be level as the insert fire is screw
fixed to the floor.
Step 3
Lay the external casing into the opening and posi-
tion it so that the front edge protrudes 20mm past
the front edge of the opening.
Step 4
Mark the drill locations and drill the holes using a
5.5mm drill bit. Fix the casing to the floor using the
self tapping screws provided.
Step 5
Lift the stove into the external casing. Remove all
internal parts as per pre-assembly instructions prior
to lifting it. The stove can be lifted into the casing
approximately 75mm first and then it can be pushed
into the final position while taking care to lift the front
edge to preserve the hearth.
Step 6
Drop the flexi flue liner down through the chimney
and into the stove.
Step 7
Lay the sealing gasket on to the flue spigot, then fit
the flue spigot to the end of the flexi flue liner using
the grub screws provided.
Step 8
Then using the M6 x 10mm screws secure the stove
to the convection chamber. Push the insert stove
against the fireplace before fully tightening these
bolts.
Step 9
Pull the flexi liner back up through the flue outlet and
fix the flue spigot into position using the M8 bolts
provided. It may be necessary to cut a prop to hold
the spigot in place while the fixings are being
240mm - 320mm
attached.
Step 10
Complete the installation of the flexi flue at the top of
the chimney in accordance with the manufacturers
instructions.
NOT FULLY LINED CHIMNEY (Using Closure
Plate & Pipe Extension)
Chimney Connectors
Offset Adaptor
Min 380mm
Step 1
Prepare the fireplace area with millner brick
removal. Ensure the opening is suitable for fitting of
the insert stove opening required, i.e. remove fire
surround trim if fitted. See Fig.4.
Step 2
Ensure the floor area is level with the hearth, this
area needs to be level as the insert fire is screw
fixed to the floor.
Step 3
Measure the distance to the flue outlet of the stove
and compare to the chimney, decide on best orien-
tation of the offset adaptor.
4
Extension Pipe
15 degree Adaptor
Fig.5
Fig.6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents