STEP 4
CONNECT RANGE TO GAS
Assure that gas supply is turned off at the shut-off
valve:
• Connect flexible metal connector to incoming gas line
pipe stub located on the left side on the bottom back
of the range.
• Turn on gas and check for leaks:
– Use a liquid leak detector at all joints and
connections in the system.
Installation
NOTE: This range is equipped with a gas shut-off valve
located behind the kick plate. This valve is to be used
in the event that service is required in the future.
Pipe Stub
11
CAUTION:
Do not use a flame to check for gas leaks.
MISE EN GARDE :
Il ne faut pas utiliser de flamme pour
vérifier s'il y a des fruites.