POWER SUPPLY LOCATIONS

Gas Supply:
• The natural gas models are designed to operate at 5"
water column pressure. A regulator is required at the
natural gas source to provide a maximum of 7" water
pressure to the cooktop regulator.
• The liquid propane models are designed to operate at
10" water column pressure. A regulator is required at
the LP source to provide a maximum of 14" water
pressure to the cooktop regulator.
• These gas ranges are supplied with 1/2" NPT female
gas connection located at the left rear corner.
• A minimum 5/8" dia. metal flexible line is required.
• Locate pipe stub on the back wall as illustrated.
– Use 5-foot, 5/8" long flexible gas supply line.
• Install a manual shut-off valve in the gas line, in an
easily accessible location.
4" for 30"/36" Models
8" for 48" Models
12"
2" Maximum
Protrusion From
Wall For Gas Supply
Gas Supply
Electric Supply:
These ranges must be supplied with 208/240 volt, 60 Hz.,
and connected to an individual, properly grounded
branch circuit protected by a circuit breaker or time
delay fuse (50 amp for 48" ranges, 30 amp for 36" ranges
and 25 amps for 30" ranges). The receptacle must be
a NEMA 14-50R device to accept the 4-prong plug
supplied with the range.

Installation Preparation

Flex Line
to Range
4" for 30"/36"
8" for 30" Models
Models
12" for 36" Models
16" for 48" Models
8" for 48"
Models
Electrical
Supply
NEMA 14-50R
Receptacle
1-1/2"
If the electrical service provided does not meet the
above specifications, it is recommended that a
licensed electrician install an approved outlet.
• Locate the electric supply as illustrated.
If this range must be connected to an electrical
system which utilizes a single conductor for ground
and neutral (3 wire system), the grounding jumper at
the terminal block must be connected. The grounding
jumper is located behind the front kick panel.
dotée d'un conducteur de terre distinct (système à
4 fils).
Si cette cuisinière doit être connectée à un système
électrique qui utilise un conducteur simple pour la
mise à la terre et le conducteur neutre (système à
3 fils), il faut alors connecter le cavalier de terre sur
la plaque à bornes. Le cavalier de terre est situé
derrière le panneau de protection frontal.
4"
To connect grounding jumper:
• Disconnect restraining clip holding jumper.
• Connect green jumper to open terminal on
neutral (white) portion of the terminal block.
7
WARNING:
equipped for use with an electrical supply
which uses a separate grounding conductor
(4 wire system).
AVERTISSEMENT :
Étant donné sa conception, la cuisinière
exige que l'alimentation électrique soit
Green
Red
Connect Here
Terminal Block
The range is
White
Black